Cleveland Range KET-3-T manual Vacuum Leak Test Procedure, Marine Lock Testing Procedure

Page 21

VACUUM LEAK TEST

PROCEDURE

If the kettle will not hold vacuum, test for leaks at:

A.Water Level Probe (Remove bottom cover).

B.Pressure Relief Valve.

C.Pressure Gauge.

LEAK TEST PROCEDURE:

1.Heat kettle until unit cycles off.

2.Shut off power to the kettle at the fused disconnect switch.

3.Spread Bubble Type Leak Detector over suspected areas and watch closely for bubbles.

4.Repair areas as required.

WATER LEVEL

PROBE

PRESSURE

GAUGE

PRESSURE

RELIEF VALVE

REPAIRING LEAKS IN STEAM JACKETED KETTLE FITTINGS

If unit will not hold a vacuum the most likely cause is a leak at one of the fittings.

Often, the easiest way to eliminate a leak is reseal the suspect areas.

1. Water Level Probe

Remove, clean threads, apply teflon thread sealant and reinstall.

2.Pressure Relief Valve A/ Inspect for signs of leaks. Replace if required.

 

B/

Remove, clean threads, apply teflon thread sealant and reinstall.

3. Pressure Gauge

A/

Inspect face of gauge. If it contains moisture on the inside of face replace.

 

B/

Remove, clean threads, apply teflon thread sealant and reinstall.

MARINE LOCK TESTING PROCEDURE

1.Check that lock clears stop pin on side box without rubbing when kettle is tilted (Figure A).

2.Check side to side play. Lock should remain fully over stop pin when pushed to it's maximum side to side play (Figure B).

3.Check that the kettle when pushed fully upright moves the lock to a closed position. To check this:

A/ Hold the latch firmly in the unlocked position while tilting the kettle back to an upright position.

B/ The kettle sidebox will force the lock into a new position.

C/ Hold the lock in this position and try to tilt the kettle forward. The latch should prevent the kettle from tilting.

Stop Pin on

SideboxMarine Lock (Latch)

Figure A

 

 

Side to Side Play

(Side View)

 

 

 

 

 

 

Lockwasher

Locknut

Side Box

Shoulder Bolt

Figure B

Console

(Top View)

 

 

 

4.Check shoulder bolt is firmly seated against console body.

5.Check on inside of console box that shoulder bolt locknut is secure.

19

Image 21
Contents Operators Manual Table of Contents Installation InstallationGeneral InspectionAssembly Wire ConnectionElectrical Installation Checks CleaningWater Item # Description Function Operating InstructionsApproximate Boiling Times Operating the KettleCleaning Instructions Care and CleaningMarine Lock Job Cleaning Agent Comments Recommended Cleaners for Specific SituationsService Parts Faucet AssemblyWarranty Item no Description Kettle Bottom & SideItem no Description QTY Cord & Plug OptionConsole Components & Marine Lock Item no Description QTY Gallon Kettle only Tilting Gearbox AssemblyElectrical Panel Inspection and Maintenance Check List MaintenanceBearing Lubricating Procedure Pressure Relief Valve Periodic Testing Procedure Calibrating ProcedureKettle Venting Instructions Reservoir Fill ProceduresVacuum Leak Test Procedure Repairing Leaks in Steam Jacketed Kettle FittingsMarine Lock Testing Procedure Possible Causes Diagnostic GuidePossible Causes Still exists, replace defective control box Wiring Diagram Gallon Symbol Legend page 1 Symbol Legend page 2