Cleveland Range KET-3-T manual Water, Installation Checks, Cleaning

Page 5

WATER

The sealed jacket of the electric kettle is precharged with the correct amount of a water based formula, and therefore, no water connection is required to the kettle jacket. The kettle can be equipped with optional hot and/or cold water faucet, requiring 1/2" copper tubing as supply lines.

INSTALLATION CHECKS

Although the kettle has been thoroughly tested before leaving the factory, the installer is responsible for ensuring the proper operation of kettle once installed.

Visual Checks

1.Check Marine Lock. See Marine Lock Testing Procedure (page 19).

2.Check Tilting:

A/ Handle is in place and firmly tightened. B/ Kettle tilts smoothly and freely.

3.Insure there are:

A/ Four screws securely holding the console cover.

B/ The bottom cover is in place and held with a nut.

Performance Checks

1.Supply power to the kettle by placing the fused disconnect switch to the "ON" position.

 

 

150

200

 

 

100

250

 

 

 

20

 

50

30

 

10

40

300

 

 

 

 

 

0

0

 

50

 

 

I

 

 

 

R

 

 

350

 

A

 

 

 

T

 

 

 

 

N

 

60

 

 

E

 

 

 

 

V

 

 

 

psi 400

kPa

2.Before turning the kettle on, read the Vacuum/Pressure Gauge (2). The gauge's needle should be in the green zone. If the needle is in the "VENT AIR" zone, follow Kettle Venting Procedure on page 18 of this manual.

3.Turn the kettle's ON/OFF Switch/Solid State Temperature Control (5) to "1" (Min.). The Heat Indicator Light (Green) (6) should remain lit, indicating the element is on, until the set

temperature is reached (130°F/54°C). Then the

green light will cycle on and off, indicating the element is cycling on and off to maintain temperature.

4.Tilt the kettle forward. The Low Water Indicator Light (Red) (4) should be lit when the kettle is in a tilted position. This light indicates that the element has automatically been shut off by the kettle's safety circuit. This is a normal condition when the kettle is in a tilted position.

5.Raise the kettle to the upright position. The Low Water Indicator Light (Red) (4) should go out when the kettle is upright. If the red light remains lit in the upright position, it indicates a low water condition, and water must be added to the reservoir before the kettle can be operated. Refer to the Reservoir Fill Procedures on page 18 of this manual.

6.Turn the ON/OFF Switch/Solid State Temperature Control (5) to "10" (Max.) and allow the kettle to preheat. The green light should remain on until the set temperature (260°F/127°C) is reached. Then the green light will cycle ON and OFF, indicating the element is cycling ON and OFF to maintain temperature. Fill the kettle with cold water to the steam jacket’s welded seam. Refer to the Temperature Range Chart on page 5 for the time required to bring the water to a boil.

7.When all testing is complete, empty the kettle and turn the ON/OFF Switch/Solid State Temperature Control (5) to the “OFF” position.

CLEANING

After installation the kettle must be thoroughly cleaned and sanitized prior to cooking. See complete cleaning instructions on page 6 of this manual.

3

Image 5
Contents Operators Manual Table of Contents Installation InstallationGeneral InspectionElectrical AssemblyWire Connection Water Installation ChecksCleaning Item # Description Function Operating InstructionsApproximate Boiling Times Operating the KettleMarine Lock Cleaning InstructionsCare and Cleaning Job Cleaning Agent Comments Recommended Cleaners for Specific SituationsWarranty Service PartsFaucet Assembly Item no Description Kettle Bottom & SideItem no Description QTY Cord & Plug OptionConsole Components & Marine Lock Item no Description QTY Gallon Kettle only Tilting Gearbox AssemblyElectrical Panel Inspection and Maintenance Check List MaintenanceBearing Lubricating Procedure Pressure Relief Valve Periodic Testing Procedure Calibrating ProcedureKettle Venting Instructions Reservoir Fill ProceduresMarine Lock Testing Procedure Vacuum Leak Test ProcedureRepairing Leaks in Steam Jacketed Kettle Fittings Possible Causes Diagnostic GuidePossible Causes Still exists, replace defective control box Wiring Diagram Gallon Symbol Legend page 1 Symbol Legend page 2