Range has been grounded at the factory to the center (nickel plated) terminal of the terminal block in accordance with the National Electrical Code (section 2560). When a separate ground is required by local code, disconnect the grounding strap from the terminal block. Ground frame by connecting a grounding wire to range frame using only the grounding screw removed from the grounding strap.

Neutral terminal connect wire with white insulation

Power terminals

(240 V)

\

Ground

strap

Power lead connect wire with black or red insulation and brass terminal

Terminal Block

Installing 3-Wire Power Cord

Refer to power cord instructions if available for additional information.

1.Remove rear wire cover on rear of range.

2.Place strain relief (winged clamp) in cord access hole below terminal block.

Strain relief is supplied with cord. Place wings through hole, entering from bottom. Screw holes in clamp should be below mounting panel. Place cord through strain relief.

3.Attach neutral (center) or white wire to center terminal on terminal block.

4.Attach power lead, red wire or black wire to left side power terminal.

5.Attach power lead, red wire or black wire to the right side power terminal.

6.Afterwires have been placed on terminals, attach with hex nuts provided.

Firmly tighten to ensure proper electrical connection.

7.Place screw through strain relief and tighten.

8.Replace rear wire cover.

Wires from range

(Number of wires on each terminal can vary)

AI B

A

Terminal block is approved for copper wire connection

only, NOT aluminum wiring. If aluminum house wiring is to be connected, the following procedure is suggested.

1.Connect length of copper building wire to range terminal block with ring terminals.

2.Splice copper wires to aluminum wiring using connectors which are designed certified by Underwriter's Laboratories and recognized for joining copper to aluminum. Follow the connector manufacturer's recommended procedure.

3.Wire used, location and enclosure of splices must conform to local codes.

Wires from power cord

APower lead tenninal (Connect black o1"red insulated wire and secure with brass nut.)

BNeutral terminal (Connect insulated white insulated wire and secure with brass nut.)

Installing 3-wire Power Cord

Image 7
Contents Customer Please Read Manual Before Operating Range InstallerContents IM Portant Safety Information Case of Fire PrecautionsCabinet Opening InstallationPacking Material Range LocationLine Voltage Requirements Power Cord RequirementsPower Supply Location Irregular Cabinet and Countertop HeightsAI B Wires from power cord Installing 4-Wire Power CordLevel Range Converting 3-Wire to 4-Wire Power CordAnti-tip Bracket Installation Removal and Replacement of RangeOperation Range FeaturesPanel Range ControlCooking with Surface Elements Surface Element SettingsType Temperature Utensil Material CharacteristicUtensils Oven Control TimerPrepare to Bake Setting Electronic ClockSetting Electronic Timer Resetting and Canceling TimerBaking Adjusting Factory Set Baking TemperatureBroiling Prepare for Self-cleanAfter Self-cleaning Cycle Self-cleaningPoultry Roasting Guide Oven TemperatureCooking Guide Baking GuideThickness Rack position Food Oven Temperature Cooking TimeBeef and Pork Roasting Guide Broiling GuideRemoving Panel Some Models Care and CleaningRemoving Oven Door Replacing Oven Light Removing Storage Drawer Some ModelsPart Materials to Use General Directions CleaningCause Cleaning Smoothtop RangetopTo Remove Problem Check Before Calling For ServiceWarranty Page Page Quick Reference Instructions