Amana ART6112, ART6002, ARR6202, ARR6102 Installing 4-Wire Power Cord, Wires from power cord

Page 8

Installing 4-Wire Power Cord

WARNING

To avoid the risk of severe electrical shock or death, ground wire must be attached to frame of range, using ground screw provided. Ground wire must not contact any other terminal.

1.Remove rear wire cover on back of range.

2.Place strain relief (winged clamp) in cord access hole below terminal block.

Strain relief is supplied with cord. Place wings through hole entering from bottom.

Screw holes in clamp should be below mounting panel.

3.Remove green ground screw (retain for use in step 8) and unscrew brass nut on center terminal. Remove grounding strap.

Wires from range

(Number of wires on each terminal can vary)

Center terminal II nut

Grounding strap

Green ground screw

Remove Green Ground Screw

4.Place cord through strain relief.

5.Attach cord neutral (center) or white wire to center terminal on terminal block. Secure with hex nuts

provided. See "Attach 4-wire Power Cord" illustration.

6.Attach power lead, red wire or black wire to left terminal. Secure with hex nuts provided.

7.Attach power lead, red wire or black wire to right terminal. Secure with hex nuts provided.

Wires from range

Number of wires on each terminal can vary)

AA

)

Wires from power cord

_Power lead terminal (Connect black or red insulated wire and secure with brass nut.)

B_eutral terminal (Connect insulated white insulated wire and secure with brass nut.)

Attach 4-wire Power Cord

. Position grounding strap down and away from terminal block. Attach green or bare wire and grounding strap to back of range using green ground screw previously removed in step 3.

Wires from range

(Number of wires on each terminal can vary)

Wires from power cord

_Ground screw (Connect green insulated wire and secure with

screw.)

Position Grounding Strap

9.Firmly tighten all connections to ensure proper electrical connection.

10.Place screw through strain relief, tighten, and replace rearwire cover.

Image 8
Contents Please Read Manual Before Operating Range Installer CustomerContents IM Portant Safety Information Precautions Case of FireInstallation Packing MaterialRange Location Cabinet OpeningPower Cord Requirements Power Supply LocationIrregular Cabinet and Countertop Heights Line Voltage RequirementsAI B Installing 4-Wire Power Cord Wires from power cordConverting 3-Wire to 4-Wire Power Cord Anti-tip Bracket InstallationRemoval and Replacement of Range Level RangeRange Features OperationRange Control PanelSurface Element Settings Cooking with Surface ElementsUtensils Utensil Material CharacteristicType Temperature Timer Oven ControlSetting Electronic Clock Setting Electronic TimerResetting and Canceling Timer Prepare to BakeAdjusting Factory Set Baking Temperature BakingPrepare for Self-clean BroilingSelf-cleaning After Self-cleaning CycleOven Temperature Cooking GuideBaking Guide Poultry Roasting GuideFood Oven Temperature Cooking Time Beef and Pork Roasting GuideBroiling Guide Thickness Rack positionCare and Cleaning Removing Oven Door Replacing Oven LightRemoving Storage Drawer Some Models Removing Panel Some ModelsCleaning Part Materials to Use General DirectionsTo Remove Cleaning Smoothtop RangetopCause Before Calling For Service Problem CheckWarranty Page Page Quick Reference Instructions