Electronic Functional Description
Freezer Temp Pad
1.Activate freezer mode by pressing Freezer Temp pad. Freezer indicator light will glow. Freezer temperature will be displayed. Factory setting
is “5” .
2.Activate temperature setting area of display by pressing Freezer Temp pad.
Ref Temp Pad
1.Activate refrigerator mode by pressing Ref Temp pad. Refrigerator indicator light will glow. Refrigerator set temperature will be displayed. Factory setting is “5”.
2.Activate temperature setting area of display by pressing Ref Temp pad.
Vacation Pad
Vacation mode defrosts refrigerator less often during extended
Max Ref Pad
Activate max ref mode by pressing Max Ref pad. Max Ref indicator light will glow. Refrigerator temperature will go to level 9 (coldest) for 10 hours or until Max Ref pad is pressed again. To adjust Max Ref time see “Mode B Functions, Max Ref Run Time Duration Adjustment”.
Max Frz Pad
Activate Max Frz mode by pressing Max Frz pad. Max Frz indicator light will glow. Freezer temperature will go to level 9 (coldest) for 24 hours or until Max Frz pad is pressed. To adjust Max Frz time see “Mode B Functions, Max Frz Run Time Duration Adjustment”.
Alarm Off Pad
1.Deactivate high temperature and door open alarm by pressing Alarm Off pad.
2.Deactivate door open alarm by pressing Alarm Off pad for 3 seconds. Activate door open alarm by pressing Alarm Off pad for 3 seconds.
3.Deactivate flashing lights (power up alarm) after refrigerator is first plugged in or after power outage by pressing Alarm Off pad.
Display Off Pad
Deactivate temperature indication area of display by pressing Display Off pad.
Door Open Alarm
1.Door open alarm sounds and indicator light blinks if refrigerator or freezer door is open for more than 3 minutes. Deactivate door open alarm by pressing Alarm Off pad or by closing refrigerator or freezer door.
2.Door alarm delay can be adjusted.
High Temp Alarm
High temperature alarm sounds and indicator light glows if freezer temperature goes above 15°F
•Deactivate alarm by pressing Alarm Off pad.
Temperature Control Operation
•For a temperature setting, outputs will be turned off/on based upon cutin/cutout temperatures, determined by resistance levels of freezer and refrigerator thermistors.
Refrigerator and Freezer Thermistor
Part # C8983701
Temp | Resistanc | Temp | Resistanc | ||
°F | (°C) | Ohms | °F |
| Ohms |
|
|
| (°C) |
|
|
|
|
|
|
|
|
| 495600 | 36 | (2) | 87510 | |
|
|
|
| ||
|
|
|
|
|
|
| 418200 | 38 | (3) | 82740 | |
|
|
|
| ||
|
|
|
|
|
|
| 354000 | 39 | (4) | 78300 | |
|
|
|
| ||
|
|
|
|
|
|
| 300600 | 43 | (6) | 74100 | |
|
|
|
| ||
|
|
|
|
|
|
| 256200 | 45 | (7) | 70170 | |
|
|
|
| ||
|
|
|
|
| |
5 | 218850 | 46 | (8) | 66450 | |
|
|
|
|
|
|
10 | 187470 | 48 | (9) | 62970 | |
|
|
|
|
|
|
16 | 161040 | 50 |
| 59670 | |
|
|
| (10) |
|
|
|
|
|
|
|
|
19 | 138690 | 55 |
| 52290 | |
|
|
| (13) |
|
|
|
|
|
|
|
|
25 | 119760 | 61 |
| 45900 | |
|
|
| (16) |
|
|
|
|
|
|
|
|
November 1996 | 27 | RS1200001 |