Machine Compartment Disassembly Procedures
Condensate Drain Pan
1.Remove toe grille plate by removing screws.
2.Pull drain pan forward away from condenser.
Condenser
1.See Compressor, Condenser, Condenser Fan Access.
2.See Condenser Fan Motor, steps 1-3.
3.Remove three 1/4" hex head screws that mount condenser to machine compartment floor.
4.Score capillary tube at drier and break.
5.Unbraze condenser inlet.
6.Slide condenser assembly out.
7.Unbraze 3/16" copper tube from condenser to drier to be reused on replacement condenser and drier.
Power Disconnect Switch
1.See Machine Compartment Access.
2.Remove leads.
3.Pop switch out through front.
Showroom Switch
1.See Low and High Voltage Board and Showroom Switch Access.
2.Remove screws and pull switch down.
3.Remove leads.
RS1200001 | 38 | November 1996 |