Electronic Functional Description
6.Conventional/adaptive defrost mode can be selected by toggling Vacation pad while in Mode B. When vacation annunciator glows, adaptive defrost system has been selected. When vacation annunciator doesn’t glow, conventional defrost system is used. Conventional defrost mode uses 8 hour CRTD value.
7.Automatic keyboard disable activated/deactivated is toggled in Mode B with Display Off pad. If high temperature indicator glows, keyboard will disable after 10 minutes. If high temperature indicator doesn’t glow, keyboard is always enabled. Do not leave keyboard in a permanently enabled mode.
8.Forced defrost is activated by pressing and holding Alarm Off pad for 3 seconds. Defrost function will begin. Program changes will be saved permanently in EEPROM and program mode will exit to run mode.
9.Forced pulldown can be made in Mode B by pressing and holding Max Frz pad 3 seconds. Refrigeration function will begin. Program changes will be saved permanently EEPROM. Compressor, evaporator fan, damper heater, and condenser fan will come on.
Exiting Program Mode
Deactivate program mode by pressing and holding Display On pad for 3 seconds. Any changes made while working in program mode will be saved and audio annunciator will beep 3 times. Program mode will be automatically exited if there is no key closure for 10 minutes. However, any changes made will not be saved permanently if program mode is exited in this manner.
RS1200001 | 30 | November 1996 |