Perlick H50IMS-R, H50IMS-ADR, H50IMS-ADL, H50IMS-L, H50IMW-AD manual BushingGasket Hinge

Page 17

7)Remove the bushings from hinge (C1) and hinge (C2) (the hinges attached to the door). See Fig. 9.

8)Remove the gasket from the door. See Fig. 10.

BushingGasket

Hinge

Fig. 9

Fig. 10

9)Temporarily fasten the overlay panel to the door using 2 of the M4×25 pan head screws provided. See Fig. 11.

CAUTION

Ensure that the back surface of overlay panel is flat before attaching.

10)Mark the centerpoint of the hinge (C1) and hinge (C2) holes that extend over the overlay panel. See Fig. 12.

Screws

Hinge

Door

Overlay Panel

Mark the center point.

Fig. 11

Fig. 12

11)Remove the overlay panel from the door.

12)Drill 3/8" diameter holes 1/4" (7 mm) deep where you marked on the overlay panel to accommodate the hinge (C1) and hinge (C2) bushings.

17

Image 17
Contents Perlick Contents Serious injury Important Safety InformationIndicates important information about the use and care UnitSpecifications A. Construction Nameplate Rating Perlick ICE MakerH50IMS-R, H-50IMS-L Dimensions/ConnectionsH50IMW H50IMS-ADL, H50IMS-ADR H50IMW-AD Checks Before Installation II. Installation and Operating InstructionsLocation GeneralBetween a Cabinet and a Wall or Tall Cabinet Built-In Installation SiteA Corner Parts H50IMW Overlay Panel Specification Overlay Panel SpecificationH50IMW-AD Overlay Panel Specification Fabrication of Overlay Panel Screws Top Panel Notch Hinge B Filler BushingGasket Hinge Attachment of Overlay Panel to Door Bushing Gasket Electrical Connection SetupWater Supply and Drain Connections Final Checklist Startup Cleaning and Sanitizing Instructions III. Cleaning and MaintenanceCleaning Solution Cleaning ProcedureTabs Sanitizing Procedure Sanitizing SolutionDischarge Tube Caps Spray Assembly Separator Slope Rail Stainless Steel Exterior MaintenanceStorage Bin and Scoop CondenserPreparing the Icemaker for Long Storage 