Perlick H50IMS-ADL, H50IMS-ADR, H50IMS-L, H50IMW-AD, H50IMS-R manual Setup, Electrical Connection

Page 20

D.Setup

1)Position the icemaker in the selected permanent location.

2)Level the icemaker from side-to-side and front-to-rear by adjusting the feet.

E.Electrical Connection

WARNING

1.Electrical connection must meet national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, fire, or severe damage to equipment.

2.This unit requires an independent power supply. See the nameplate for proper voltage and breaker/fuse size. Failure to use a proper breaker or fuse can result in a tripped breaker, blown fuse, or damage to existing wiring. This could lead to heat generation or fire.

3.THIS APPLIANCE MUST BE GROUNDED: This unit is equipped with a 3-prong grounding plug to reduce the risk of potential shock hazards. It must be plugged into a properly grounded, independent wall outlet. If the outlet is a 2-prong outlet, it is your personal responsibility to have a qualified electrician replace it with a properly grounded, independent 3-prong wall outlet. Do not remove the ground prong from the power cord and do not use an adapter plug. Failure to follow these instructions may result in death, electric shock, or fire.

4.Do not use an extension cord.

5.Make sure the control switch is in the "OFF" position before plugging in or unplugging the unit to reduce the risk of electric shock.

6.Do not use a unit with a damaged power cord. The power cord should not be altered, jerked, bundled, weighed down, pinched, or tangled. Such actions could result in electric shock or fire. To unplug the unit, be sure to pull the plug, not the cord, and do not jerk the cord.

7.To reduce the risk of electric shock, do not touch the plug or control switch with damp hands.

8.The GREEN ground wire in the factory-installed power cord is connected to a screw on the rear panel where the cord enters the unit. If it becomes necessary to remove or replace the power cord, be sure to connect the power cord's ground wire to this screw upon reattachment.

Usually an electrical permit and services of a licensed electrician are required.

The maximum allowable voltage variation is ±10 percent of the nameplate rating.

For optional drain pump installation, refer to the instruction manual included with the pump.

20

Image 20
Contents Perlick Contents Important Safety Information Serious injuryIndicates important information about the use and care UnitSpecifications A. Construction Perlick ICE Maker Nameplate RatingDimensions/Connections H50IMS-R, H-50IMS-LH50IMW H50IMS-ADL, H50IMS-ADR H50IMW-AD II. Installation and Operating Instructions Checks Before InstallationLocation GeneralBetween a Cabinet and a Wall or Tall Cabinet Built-In Installation SiteA Corner Parts Overlay Panel Specification H50IMW Overlay Panel SpecificationH50IMW-AD Overlay Panel Specification Fabrication of Overlay Panel Screws Top Panel Notch Hinge B Filler BushingGasket Hinge Attachment of Overlay Panel to Door Bushing Gasket Setup Electrical ConnectionWater Supply and Drain Connections Final Checklist Startup III. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Solution Cleaning ProcedureTabs Sanitizing Solution Sanitizing ProcedureDischarge Tube Caps Spray Assembly Separator Slope Rail Maintenance Stainless Steel ExteriorStorage Bin and Scoop CondenserPreparing the Icemaker for Long Storage 