Part 3 ELECTRICAL CONNECTIONS

Third, connect the wires.

If bare wire is used, connect with adapter lugs as shown in Figures 11 and 12.

1.Insert the end of each wire (L1, L2, Neutral) into the each lug. Tighten the clamping screw.

2.Remove the 3 nuts from the terminal block and retain them.

3.Attach the lug with white wire (Neutral) to the center terminal block bolt.

4.Attach the lug with black wire (L2) to the left terminal block bolt.

5.Attach the lug with red wire (L1) to the right terminal block bolt.

6.Tighten 3 nuts (removed earlier) securely onto the terminal block.

7.Go to page 8.

4-wire connection: conduit

1.Follow the instructions under “Install the conduit cord as follows” on page 6 to correctly install the strain relief.

You must install the conduit with a strain relief.

2.Cut the center portion of ground strap as shown Figure 13.

Do not discard any screws.

If bare wire is used, connect with adapter lugs as shown in Figures 11 and 13.

3.Insert the end of green wire (ground) from conduit into the lug and tighten the clamping screw. Attach the lug to the GND hole below terminal block with ground screw (removed earlier).

4.Insert the end of each wire (L1, L2, Neutral) into each separate lug. Tighten the clamping screw.

5.Remove the 3 nuts from the terminal block. Remove the ground screw and retain them.

6.Attach the lug with white wire (Neutral) to the center terminal block bolt.

7.Attach the lug with black wire (L2) to the left terminal block bolt.

8.Attach the lug with red wire (L1) to the right terminal block bolt.

9.Tighten 3 nuts (removed earlier) securely into the terminal block.

10.Go to page 8.

Reinstall the

Conduit connection plate

BARE WIRE TORQUE SPECIFICATIONS LUG ATTACHED TO TERMINAL BLOCK - 20 IN-LB

WIRE AWG

TORQUE

10-14

20

IN-LB

8

25

IN-LB

4-6

35

IN-LB

 

 

 

FIGURE 11

3-wire connection

L2

N

L1

FIGURE 12

4-wire connection

L2

N

L1

 

 

 

G

 

FIGURE 13

7

Image 7
Contents Installation Manual Important Note to the Consumer Important Safety InstructionsImportant Notes to the Installer Before YOU BeginMinimum Dimensions Figure Part 2 Prepare to Install the RangeInstallation Drawings Clearances and Dimensions FigureConnect Range Cord Specified power-supply-cord kit ratingPart 3 Electrical Connections Electrical Connection RequirementsDo not remove the ground strap connection Wire connection with a power supply cordInstall the power cord as follows You must install the power cord with a strain reliefInstall the conduit as follows Wire connection conduitWire Reinstall Conduit connection plate Locate the bracket using the template Part 4 Install the RangeANTI-TIP Device Installation Final InstallationManual de instalación Notas importantes para el consumidor Antes DE ComenzarInstrucciones DE Seguridad MUY Importantes Notas importantes para el instaladorIlustraciones DE Instalación Holguras Y Dimensiones FiguraDimensiones Mínimas Figura Sección 2 Preparativos Para Instalar LA EstufaRequisitos DE LAS Conexiones Eléctricas Sección 3 Conexiones EléctricasCómo Conectar EL Cable DE LA Estufa No quite la conexión de la cinta de conexión a tierra Conexión de 3 alambres Con un cable de alimentaciónInstale el cable de alimentación como sigue Conexión de 4 alambres Con un cable de alimentaciónInstale el conducto portacables de la manera siguiente Conexión de 3 alambres Conducto portacablesAlambres Conexión de 4 alambres Conducto portacables Instalación DEL Dispositivo ANTI-VOLCADURAS Sección 4 Cómo Instalar LA EstufaInstalación Final