Part 3 ELECTRICAL CONNECTIONS
3-wire connection with a power supply cord
WARNING
The middle (neutral or ground) wire of the power cord or
Install the power cord as follows:
For power cord installations, Hook the strain relief over the power cord hole (13/8”) located below the rear of drawer body. Insert the power cord through the strain relief and tighten it. (Refer to Figure 5.)
You must install the power cord with a strain relief.
1.Remove the 3 nuts from the terminal block and retain them. (Refer to Figure 6.)
2.Attach the 3 wires (L1, Neutral, L2) to each terminal block bolt. Make sure that the center wire (neutral) is connected to the center position of the terminal block.
3.Tighten the 3 nuts securely into the terminal block.
Do not remove the ground strap connection.
4.Go to page 8.
WARNING
Only a
Follow the instructions under “Install the power cord as follows” on page 5 to correctly install the strain relief.
Attach the strain relief to the 1 3/8” opening in Conduit connection plate
FIGURE 5
L2 | N | L1 |
FIGURE 6
L2 | N | L1 |
| G |
|
FIGURE 7
5