attracts dust and dirt to the surface. Blotting with a clean damp cloth is recommended to remove charge.

ANTISTATIC COATINGS

For acrylic used indoors, antistatic coatings successfully prevent the accumulation of an electrostatic charge for periods of several months—if the surface is not washed or wiped down with a wet cloth. Between applications of the antistatic coatings, the parts need only be dusted with a soft clean cloth to maintain a good appearance. In use, liquid antistatic coatings should be applied in a very thin even coat. If beads appear as it is applied, the coat is too thick and the excess should be removed with another cloth. Allow the coating to dry, then bring to a high gloss with a soft cloth.

PLEXIGLASS REPAIR

plastic rod

acrylic

maskingcement tape

PARTS LIST

1" Plastic rod 3/16" diameter

Acrylic Solvent Cement (IPS weldon #16, #40 or comparable)

Masking tape & duct tape (not supplied)

INSTRUCTIONS

Note:

Cases must be leveled and set prior to joining

 

plexiglass. Cases were prejoined, leveled and set

 

at the factory to assure proper fit at the installa-

 

tion.

Step 1 Prepare front plexiglass for cement applica- tion by placing masking tape, a maximum 1/16 of an inch from the seam, on both sides front and back. Tape is to protect plexiglass from cement spill over. Scarring will occur if cement touches clear plexiglass.

Step 2 Sand edges with 60-80 grit paper. Parts must fit well with no visual gap. Keep plexiglass clean and clear of dust.

Step 3 Remove protective mask from plexiglass. Separate front plexiglass pieces enough to apply a bead of #16 cement within one edge inside of seam and plastic rod area. If Weldon #40 was supplied, refer to the instructions below.

Step 4 Realign front plexiglass and push together gently allowing cement to wet both surfaces. Insert the plastic rod until flush with top of plexiglass.

Step 5 Clamp firmly and apply tape (2" duct tape recommended) across face of seam to secure plexiglass from shifting while cement dries. Allow 24 hours for glue to cure completely, however joint will be strong enough to work on after 2 hours.

INSTRUCTIONS FOR #40 WELD-ON CEMENT

INSTRUCTIONS:

Step 1 Bring components "A" and "B" to room temperature.

Step 2 Add component "A" to component "B". Items have been pre-measured at the factory.

Step 3 Stir mixture slowly and evenly to prevent air bubbles. Mix for 1-3 minutes.

Step 4 Apply cement to one or both surfaces with applicator. Assemble immediately!

Step 5 Apply just enough pressure to remove air bubbles. Do not squeeze joint so hard as to force cement out of the joint – a dry joint may result.

Step 4 Allow to dry approximately 4 hours (at 70°). More time may be required at lower tempera- tures.

11

Image 11
Contents Esss / ESS Concealed Loss or Damage This Booklet Contains Information onShipping Damage Apparent Loss or DamageEsss Cut & Plan ViewsExterior Loading Setting and JoiningLeveling and Placement Uncrating the StandCommon END Between Unlike Cases and HOT Cases Corner WedgesESS Refrigerated DRYWaste Outlet and P-TRAP Installing Condensate DrainPlumbing Refrigerant Type Control SettingsAccess to TX Valves & Drain Lines Expansion Valve AdjustmentElectrical Circuit Identification Wiring Color CodeField Wiring & Serial Plate Amperage ElectricalStocking Joint TrimEsss Only User InformationPlexiglass & Acrylic Care Cleaning Case CleaningCleaning Glass & Mirrors Cleaning Precautions When CleaningInstructions Parts ListAntistatic Coatings Plexiglass RepairReplacing Fluorescent Lamps ReplacementTips & Troubleshooting For Prompt ServiceModel Specifications2CaselayoutwithT8Lights Electrical Schematics0100-04-125 PigtailcaseSingle 0101-04-125 Solenoid Gfci ASC 12CasewithT8Lights Appendix B. Application Recommendations Appendix A. Temperature GuidlinesType of Refrigerator Typical Entering Air Temperature AppendicesAppendix D. Recommendations to user Are the refrigerant controls incorrectly adjusted?IGSS-ESS/ESSS-0303 Limited Warranty Model Serial Number

IGSS-ESS, ESSS-0303 specifications

The Hussman ESSS-0303 and IGSS-ESS are revolutionary products in the world of commercial refrigeration, known for their ability to deliver energy-efficient performance while ensuring optimal food preservation. These systems feature cutting-edge technology that caters to the needs of supermarkets, convenience stores, and other retail environments where refrigeration is crucial.

One of the primary features of the Hussman ESSS-0303 is its advanced energy management capabilities. The system is equipped with intelligent controls that analyze energy consumption patterns, optimizing performance in real time. This not only helps to reduce operational costs but also contributes to sustainability efforts by minimizing energy waste.

Another significant aspect of the ESSS-0303 is its ability to maintain precise temperature control. This is achieved through a combination of high-quality insulation and advanced refrigeration technology, which ensures that products remain fresh for longer periods. The unit offers temperature ranges specifically designed for various applications, whether it be for dairy products, frozen foods, or fresh produce.

The Hussman IGSS-ESS, on the other hand, is designed to integrate seamlessly with existing refrigeration setups, allowing for a smooth transition to newer technologies. Its modular design allows businesses to easily expand their refrigeration capabilities without the need for extensive renovations. In addition, the IGSS-ESS features remote monitoring capabilities, which enables store managers to track performance and diagnose potential issues from a distance, ensuring minimal downtime.

These systems are also built with user-friendliness in mind. The intuitive control interface allows for easy programming and adjustments, empowering staff to efficiently manage the refrigeration environment. Furthermore, Hussman has made durability a priority; both the ESSS-0303 and IGSS-ESS are constructed from robust materials, ensuring longevity even in high-demand retail settings.

In summary, the Hussman ESSS-0303 and IGSS-ESS offer enhanced energy efficiency, precise temperature control, integration capabilities, remote monitoring, and user-friendly interfaces. These characteristics make them ideal choices for retailers seeking to optimize their refrigeration solutions while maintaining product quality and reducing energy costs. As businesses continue to prioritize sustainability and efficiency, the Hussman range stands out as a reliable partner in commercial refrigeration technology.