hussman ESSS-0303, IGSS-ESS manual Plumbing, Waste Outlet and P-TRAP, Installing Condensate Drain

Page 6

IGSS-ESS/ESSS-0303

Plumbing

WASTE OUTLET AND P-TRAP

The waste outlet is located off the center of the case on one side allowing drip piping to be run lengthwise under the fixture.

A 1-1/2" P-trap and threaded adapter are supplied with each fixture. The P-trap must be installed to prevent air leakage and insect entrance into the fixture.

NOTE: PVC-DWV solvent cement is recommended. Follow the manufacturer’s instructions.

INSTALLING CONDENSATE DRAIN

Poorly or improperly installed condensate drains can se- riously interfere with the operation of this refrigerator, and result in costly maintenance and product losses.Please follow the recommendations listed below when installing condensate drains to insure a proper installation:

1.Never use pipe for condensate drains smaller than the nominal diameter of the pipe or P-trap supplied with the case.

2.When connecting condensate drains, the P-trap must be used as part of the condensate drain to prevent air leakage or insect entrance. Store plumb- ing system floor drains should be at least 14" off the center of the case to allow use of the P-trap pipe

section. Never use two water seals in series in any one line. Double P-traps in series will cause a lock and prevent draining.

3.Always provide as much down hill slope (“fall”) as possible; 1/8" per foot is the preferred minimum. PVC pipe, when used, must be supported to main- tain the 1/8" pitch and to prevent warping.

4.Avoid long runs of condensate drains. Long runs make it impossible to provide the “fall” necessary for good drainage.

5.Provide a suitable air break between the flood rim of the floor drain and outlet of condensate drain. 1" is ideal.

6.Prevent condensate drains from freezing:

a.Do not install condensate drains in contact with non-insulated suction lines. Suction lines should be insulated with a nonabsorbent insulation material such as Armstrong’s Armaflex.

b.Where condensate drains are located in dead air spaces (between refrigerators or between a refrigerator and a wall), provide means to prevent freezing.The water seal should be insulated to prevent condensation.

6

Image 6
Contents Esss / ESS Apparent Loss or Damage This Booklet Contains Information onShipping Damage Concealed Loss or DamageCut & Plan Views EsssUncrating the Stand Setting and JoiningLeveling and Placement Exterior LoadingDRY Corner WedgesESS Refrigerated Common END Between Unlike Cases and HOT CasesInstalling Condensate Drain PlumbingWaste Outlet and P-TRAP Expansion Valve Adjustment Control SettingsAccess to TX Valves & Drain Lines Refrigerant TypeElectrical Wiring Color CodeField Wiring & Serial Plate Amperage Electrical Circuit IdentificationUser Information Joint TrimEsss Only StockingCleaning Precautions When Cleaning Case CleaningCleaning Glass & Mirrors Plexiglass & Acrylic Care CleaningPlexiglass Repair Parts ListAntistatic Coatings InstructionsFor Prompt Service ReplacementTips & Troubleshooting Replacing Fluorescent LampsSpecifications ModelElectrical Schematics 2CaselayoutwithT8Lights0100-04-125 PigtailcaseSingle 0101-04-125 Solenoid Gfci ASC 12CasewithT8Lights Appendices Appendix A. Temperature GuidlinesType of Refrigerator Typical Entering Air Temperature Appendix B. Application RecommendationsAre the refrigerant controls incorrectly adjusted? Appendix D. Recommendations to userIGSS-ESS/ESSS-0303 Limited Warranty Model Serial Number

IGSS-ESS, ESSS-0303 specifications

The Hussman ESSS-0303 and IGSS-ESS are revolutionary products in the world of commercial refrigeration, known for their ability to deliver energy-efficient performance while ensuring optimal food preservation. These systems feature cutting-edge technology that caters to the needs of supermarkets, convenience stores, and other retail environments where refrigeration is crucial.

One of the primary features of the Hussman ESSS-0303 is its advanced energy management capabilities. The system is equipped with intelligent controls that analyze energy consumption patterns, optimizing performance in real time. This not only helps to reduce operational costs but also contributes to sustainability efforts by minimizing energy waste.

Another significant aspect of the ESSS-0303 is its ability to maintain precise temperature control. This is achieved through a combination of high-quality insulation and advanced refrigeration technology, which ensures that products remain fresh for longer periods. The unit offers temperature ranges specifically designed for various applications, whether it be for dairy products, frozen foods, or fresh produce.

The Hussman IGSS-ESS, on the other hand, is designed to integrate seamlessly with existing refrigeration setups, allowing for a smooth transition to newer technologies. Its modular design allows businesses to easily expand their refrigeration capabilities without the need for extensive renovations. In addition, the IGSS-ESS features remote monitoring capabilities, which enables store managers to track performance and diagnose potential issues from a distance, ensuring minimal downtime.

These systems are also built with user-friendliness in mind. The intuitive control interface allows for easy programming and adjustments, empowering staff to efficiently manage the refrigeration environment. Furthermore, Hussman has made durability a priority; both the ESSS-0303 and IGSS-ESS are constructed from robust materials, ensuring longevity even in high-demand retail settings.

In summary, the Hussman ESSS-0303 and IGSS-ESS offer enhanced energy efficiency, precise temperature control, integration capabilities, remote monitoring, and user-friendly interfaces. These characteristics make them ideal choices for retailers seeking to optimize their refrigeration solutions while maintaining product quality and reducing energy costs. As businesses continue to prioritize sustainability and efficiency, the Hussman range stands out as a reliable partner in commercial refrigeration technology.