Refrigeration

REFRIGERANT TYPE

The standard refrigerant will be R-22 unless otherwise specified on the customer order. Check the serial plate on the case for information.

PIPING

The refrigerant line outlets are located under the case. Locate first the electrical box, the outlets are then on the same side of the case but at the opposite end. Insulate suction lines to prevent condensation drippage.

REFRIGERATION LINES

LIQUID SUCTION

3/8" O.D.

5/8" O.D.

NOTE: The standard coil is piped at 5/8" (suction); however, the store tie-in may vary depending on the number of coils and the draw the case has. Depending on the case setup, the connecting point in the store may be

5/8", 7/8", or 11/8". Refer to the particular case you are hooking up.

Refrigerant lines should be sized as shown on the refrig- eration legend furnished by the store.

Install P-traps (oil traps) at the base of all suction line ver- tical risers.

Pressure drop can rob the system of capacity.To keep the pressure drop to a minimum, keep refrigerant line run as short as possible, using the minimum number of elbows. Where elbows are required, use long radius elbows only.

CONTROL SETTINGS

See the “Case Specs” section of this guidebook for the appropriate settings for your merchandiser. Maintain these parameters to achieve near constant product tempera- tures. Product temperature should be measured first thing in the morning, after having been refrigerated overnight. For all multiplexing, defrost should be time terminated. Loadmaster valves are not recommended. Defrost times should be as follows: OFF CYCLE - One time daily for 110 minutes.The number of defrosts per day should never change.The duration of the defrost cycle may be adjusted to meet conditions present at your location.

ACCESS TO TX VALVES & DRAIN LINES

tronic expansion valves will be installed on the coil inlet, coil outlet, and in the discharge air. (Some supermarkets require a 4th sensor in the return air). Case controllers will be located in the electrical raceway or under the case

THERMOSTATIC EXPANSION VALVE LOCATION

This device is located on the same side as the refrigera- tion stub. A Sporlan balanced port expansion valve model is furnished as standard equipment,unless otherwise speci- fied by customer.

EXPANSION VALVE ADJUSTMENT

Expansion valves must be adjusted to fully feed the evapo- rator. Before attempting any adjustments, make sure the evaporator is either clear or very lightly covered with frost, and that the fixture is within 10°F of its expected operat- ing temperature.

MEASURING THE OPERATING SUPERHEAT

1.Determine the suction pressure with an accurate pressure gauge at the evaporator outlet.

2.From a refrigerant pressure temperature chart, determine the saturation temperature at the observed suction pressure.

3.Measure the temperature of the suction gas at the thermostatic remote bulb location.

4.Subtract the saturation temperature obtained in step No.2 from the temperature measured in step No.3.

3. The difference is superheat.

5. Set the superheat for 5°F - 7°F.

T-STAT LOCATION

T-Stats are located within the electrical raceway. Refer to diagram below.

ODY

 

 

S

 

B

OPTIONAL

S

 

L

OPTIONAL

OPTIONAL

MECHANICAL - Remove product from end of case. Remove product racks.Remove refrigeration and drain access panels (labeled).TX valve (mechanical only) and drain are located under each access panel at end of the case.

ELECTRONIC - The Electronic Expansion valve master and slave cylinder(s) are located within the electrical access panel(s).

ELECTRONIC EXPANSION VALVE (OPTIONAL)

A wide variety of electronic expansion valves and case controllers can be utilized. Please refer to EEV and con- troller manufacturers information sheet. Sensors for elec-

ESS

T-stats are located in the front electrical raceway and can be adjusted through the knockout hole without removing any panels.The sensing bulb is in the discharge air.

ESSS

T-stat is located in the rear electrical raceway and can be adjusted through the knockout hole without removing any panels.The sensing bulb is in the discharge air. If the op- tional front electrical raceway is installed, the T-stat is lo- cated in the font electrical raceway and can be adjusted through the knockout hole in the front closeoff without

7removing any panels.

Image 7
Contents Esss / ESS Concealed Loss or Damage This Booklet Contains Information onShipping Damage Apparent Loss or DamageEsss Cut & Plan ViewsExterior Loading Setting and JoiningLeveling and Placement Uncrating the StandCommon END Between Unlike Cases and HOT Cases Corner WedgesESS Refrigerated DRYPlumbing Installing Condensate DrainWaste Outlet and P-TRAP Refrigerant Type Control SettingsAccess to TX Valves & Drain Lines Expansion Valve AdjustmentElectrical Circuit Identification Wiring Color CodeField Wiring & Serial Plate Amperage ElectricalStocking Joint TrimEsss Only User InformationPlexiglass & Acrylic Care Cleaning Case CleaningCleaning Glass & Mirrors Cleaning Precautions When CleaningInstructions Parts ListAntistatic Coatings Plexiglass RepairReplacing Fluorescent Lamps ReplacementTips & Troubleshooting For Prompt ServiceModel Specifications2CaselayoutwithT8Lights Electrical Schematics0100-04-125 PigtailcaseSingle 0101-04-125 Solenoid Gfci ASC 12CasewithT8Lights Appendix B. Application Recommendations Appendix A. Temperature GuidlinesType of Refrigerator Typical Entering Air Temperature AppendicesAppendix D. Recommendations to user Are the refrigerant controls incorrectly adjusted?IGSS-ESS/ESSS-0303 Limited Warranty Model Serial Number

IGSS-ESS, ESSS-0303 specifications

The Hussman ESSS-0303 and IGSS-ESS are revolutionary products in the world of commercial refrigeration, known for their ability to deliver energy-efficient performance while ensuring optimal food preservation. These systems feature cutting-edge technology that caters to the needs of supermarkets, convenience stores, and other retail environments where refrigeration is crucial.

One of the primary features of the Hussman ESSS-0303 is its advanced energy management capabilities. The system is equipped with intelligent controls that analyze energy consumption patterns, optimizing performance in real time. This not only helps to reduce operational costs but also contributes to sustainability efforts by minimizing energy waste.

Another significant aspect of the ESSS-0303 is its ability to maintain precise temperature control. This is achieved through a combination of high-quality insulation and advanced refrigeration technology, which ensures that products remain fresh for longer periods. The unit offers temperature ranges specifically designed for various applications, whether it be for dairy products, frozen foods, or fresh produce.

The Hussman IGSS-ESS, on the other hand, is designed to integrate seamlessly with existing refrigeration setups, allowing for a smooth transition to newer technologies. Its modular design allows businesses to easily expand their refrigeration capabilities without the need for extensive renovations. In addition, the IGSS-ESS features remote monitoring capabilities, which enables store managers to track performance and diagnose potential issues from a distance, ensuring minimal downtime.

These systems are also built with user-friendliness in mind. The intuitive control interface allows for easy programming and adjustments, empowering staff to efficiently manage the refrigeration environment. Furthermore, Hussman has made durability a priority; both the ESSS-0303 and IGSS-ESS are constructed from robust materials, ensuring longevity even in high-demand retail settings.

In summary, the Hussman ESSS-0303 and IGSS-ESS offer enhanced energy efficiency, precise temperature control, integration capabilities, remote monitoring, and user-friendly interfaces. These characteristics make them ideal choices for retailers seeking to optimize their refrigeration solutions while maintaining product quality and reducing energy costs. As businesses continue to prioritize sustainability and efficiency, the Hussman range stands out as a reliable partner in commercial refrigeration technology.