MAINTENANCE FUNDAMENTALS, CONTINUED
Warning, disconnect power before provid- ing maintenance and service to unit. As- sembly or disassembly and servicing to be accomplished by licensed electrical con- tractor.
Evaporator Coil Fans Access and Removal
•Fans may be accessed by removing Deck (covering Fan Shroud, Fan Housing and Coil). See illustrations at right.
Light Ballast Access
Light ballast is located inside the Electrical J- Box. Electrical
Electrical
Removing Rear Doors and Perforated Acrylic Plenum.
•Note: Doors are not interchangeable.
•There is an Outer and Inner Door. The Outer door is the right hand door (from case rear). It can be identified by a stop located at the lower right hand corner to the inside of the case.
•The Inner Door is the left hand door (from case rear).
•See next page for specifics on access to and removal of thumbscrews, doors and perforated acrylic plenum.
Fan
Shroud
Coil
Fan
Housing
Coil | Fan Shroud |
|
|
| Drain |
Fan & Housing |
| |
|
|
|
Inner Door
Outer
Door
Thumb- screws holding Sliding Doors to Acrylic Plenum
R
888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com