Impulse DO4837R Clearance and AIR Flow, Service Top Cutout Dimensions Clearance Dimensions

Page 5

CLEARANCE AND AIR FLOW

Service Top Cutout Dimensions

Note: See Manual Cover for DO3637R, DO4837R, DO3623R & 4823R Service Top Cutout Dimensions.

Clearance Dimensions

The Refrigerated section must maintain airflow clear- ance. Dimensions are as follow.

1.4" Minimum Spacing from bottom of refrigeration frame to bottom of cabinet or floor required for ade- quate air flow.

2.9 1/2" Countertop / Facia enclosure space on cabi- nets or counter to allow for pullout system slide-out.

3.15" Minimum opening in back of cabinet or counter (to pull out refrigeration system).

4.Back of counter / cabinet must be vented at specific sizes to allow for proper air intake and air exhaust. See Venting Instructions sections for specifics.

5.Obstruction or restriction of air can void warranty.

Note: See Venting Instructions sections (next two pages) for more specific Air Intake and Air Exhaust clearance dimensions for Models DO3637R & DO4837R.

9 1/2” (SEE

NOTE 2)

15”

(SEE NOTES

3 & 4)

4” (SEE NOTE 1)

ABOVE ILLUSTRATION APPLIES TO BOTH

MODELS DO3637R AND DO4837R

R

888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com

5

Image 5
Contents 38 1/8L x 28 5/8D x 61 1/8H Model DO3637R Model DO4837R 38 1/8L x 28 5/8D x 37 1/4HModel DO4837R 50 1/8L x 28 5/8D x 37 1/4H 50 1/8L x 28 5/8D x 61 1/8HTable of Contents Overview and Warnings Customer Cabinet Provisions Customer Cabinet ProvisionsClearance and AIR Flow Service Top Cutout Dimensions Clearance Dimensions2 Facia Enclosure Venting Instructions for AIR Intake / Exhaust DO3637RVenting Instructions for AIR Intake / Exhaust DO4837R Page Seal Upper Display Case to Base InstallationDisplay Case Setup Case Start-Up Temperature SettingsSTART-UP and Operation Adjustable Shelf Maintenance FundamentalsShelf Assembly Removal Light FixturesRemoving Rear Doors and Perforated Acrylic Plenum Evaporator Coil Fans Access and RemovalLight Ballast Access Removing Perforated Acrylic Plenum Removing the Rear DoorsRefrigeration Fundamentals Temperature Control ModuleRefrigeration SLIDE-OUT Exploded Pictorial Technical Information Sheet Model DO3637R Technical Information Sheet Model DO4837R Technical Information Sheet Model DO3623R Technical Information Sheet Model DO4823R Troubleshooting Alarm Going Off, CPC ESC3 Daily Weekly Monthly Task Cleaning ScheduleCompressor Safety Cycle Compressor Power On DelayCPC Controller Overview Controller OverviewIndications on the Display CPC ESC3 Controller OperationCPC ESC3 SET Point Changing Instructions Viewing and Changing the Temperature Set PointChanging Other Set Points To change User set pointsWarranty Technical Service