START-UP AND OPERATION
Case Start-Up
•Plug cord into a certified electrical outlet with ground.
•Turn on the Main Power Switch. Switch is in the
•The Temperature Control Module (LED) will illuminate. Evaporator coil fans and the compressor motor should turn on.
•From the front of the case, raise the deck to confirm that the coil fans are functioning properly.
•Turn on the lights. Light Switch is in the Up- per Display interior of the case at rear right side (see illustration at right).
•First time lighting may require a short warm up period for the bulbs. Slightly dim or a flickering of new bulbs is normal.
Temperature Settings
•This case has been tested to maintain a temperature at or below 5° Celsius / 41° Fahrenheit.
•When the merchandiser is in a start up mode or has been idle for a long period of time, the unit will require 30 minutes in order to
•
•The temperature is controlled by a Tempera- ture Control Module. It is located at the
•If a temperature setting change is required,refer to the instructions for the CPC® (ESC3) Temperature Control Programming operating section of this man- ual
•Note: See Technical Data section of this manual for proper settings to maintain prod- uct temperature per model.