Impulse DO3623R, DO4823R, DO4837R, DO3637R dimensions Overview and Warnings

Page 3

OVERVIEW AND WARNINGS

OVERVIEW

The Structural Concepts® Oasis® refrigerated self-service cases are designed to merchandise packaged products at 5° Celsius / 41° Fahrenheit or less product temperatures.

These cases should be installed and operated according to the following instructions to insure proper performance.

This unit is designed for the display of products in ambient store conditions where temperatures and humidity are maintained at a maximum of 24°C / 75°F and 55% relative humidity.

WARNING

WARNING

Risk of Electric Shock.

ELECTRICAL

Disconnect Power Before Servicing Unit

HAZARD

 

WARNING

KEEP HANDS

CLEAR

WARNING

Hazardous Moving Parts.

Do Not Operate unit with covers removed.

Fan blades may be exposed when deck panel is removed. Disconnect

power before removing deck panel.

WARNING

WARNING

HOT

Evaporator Tray is Hot

 

SURFACE

 

 

CAUTION

CAUTION

Lamps have been treated to resist breakage and must be replaced with a

similarly treated lamp.

 

R

888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com

3

Image 3
Contents 50 1/8L x 28 5/8D x 61 1/8H Model DO3637R Model DO4837R 38 1/8L x 28 5/8D x 37 1/4H38 1/8L x 28 5/8D x 61 1/8H Model DO4837R 50 1/8L x 28 5/8D x 37 1/4HTable of Contents Overview and Warnings Customer Cabinet Provisions Customer Cabinet ProvisionsClearance and AIR Flow Service Top Cutout Dimensions Clearance Dimensions2 Facia Enclosure Venting Instructions for AIR Intake / Exhaust DO3637RVenting Instructions for AIR Intake / Exhaust DO4837R Page Installation Display Case SetupSeal Upper Display Case to Base Temperature Settings START-UP and OperationCase Start-Up Light Fixtures Maintenance FundamentalsAdjustable Shelf Shelf Assembly RemovalEvaporator Coil Fans Access and Removal Light Ballast AccessRemoving Rear Doors and Perforated Acrylic Plenum Removing Perforated Acrylic Plenum Removing the Rear DoorsRefrigeration Fundamentals Temperature Control ModuleRefrigeration SLIDE-OUT Exploded Pictorial Technical Information Sheet Model DO3637R Technical Information Sheet Model DO4837R Technical Information Sheet Model DO3623R Technical Information Sheet Model DO4823R Troubleshooting Alarm Going Off, CPC ESC3 Daily Weekly Monthly Task Cleaning ScheduleController Overview Compressor Power On DelayCompressor Safety Cycle CPC Controller OverviewIndications on the Display CPC ESC3 Controller OperationTo change User set points Viewing and Changing the Temperature Set PointCPC ESC3 SET Point Changing Instructions Changing Other Set PointsWarranty Technical Service