VENTING INSTRUCTIONS FOR AIR INTAKE / EXHAUST - DO3637R
BACK VIEW OF CABINET
AFTER POSITIONED ON
Warning: The minimum intake and exhaust areas must be allowed (as illustrated
below) or case temperatures may fluctuate beyond safe parameters.
NOTES:
1.BACK OF CABINET MUST BE VENTED A MINIMUM OF 13” x 13” FOR AIR INTAKE.
2.BACK OF CABINET MUST BE VENTED A MINIMUM OF 10 1/2” x 19” FOR AIR EXHAUST.
3.BACK OF CABINET MUST PROVIDE A MINIMUM OF 15” x 32” FOR MAINTENANCE ACCESS. THIS AREA (AS
DIMENSIONED BELOW) WILL ALLOW SERVICE TO SLIDE OUT CONDENSING UNIT.
4.SEE REFRIGERATION FUNDAMENTALS FOR VIEW OF CONDENSING UNIT AFTER
5. AIR INTAKE (ILLUSTRATED BELOW).
6.AIR EXHAUST (ILLUSTRATED BELOW).
9 1/2” FACIA ENCLOSURE
13” MINIMUM AIR INTAKE SPACE
15” MINIMUM MAINTENANCE ACCESS SPACE
9 1/2”
19” MINIMUM AIR EXHAUST SPACE
13” MINIMUM | |
AIR | |
INTAKE SPACE | |
32” | MINIMUM MAINTENANCE |
| |
| ACCESS SPACE |
10 1/2” MIN. AIR EXHAUST SPACE
R