Impulse DO4823R Venting Instructions for AIR Intake / Exhaust DO3637R, Facia Enclosure

Page 6

VENTING INSTRUCTIONS FOR AIR INTAKE / EXHAUST - DO3637R

BACK VIEW OF CABINET

AFTER POSITIONED ON

CUSTOMER-SUPPLIED COUNTER/BASE

Warning: The minimum intake and exhaust areas must be allowed (as illustrated

below) or case temperatures may fluctuate beyond safe parameters.

NOTES:

1.BACK OF CABINET MUST BE VENTED A MINIMUM OF 13” x 13” FOR AIR INTAKE.

2.BACK OF CABINET MUST BE VENTED A MINIMUM OF 10 1/2” x 19” FOR AIR EXHAUST.

3.BACK OF CABINET MUST PROVIDE A MINIMUM OF 15” x 32” FOR MAINTENANCE ACCESS. THIS AREA (AS

DIMENSIONED BELOW) WILL ALLOW SERVICE TO SLIDE OUT CONDENSING UNIT.

4.SEE REFRIGERATION FUNDAMENTALS FOR VIEW OF CONDENSING UNIT AFTER SLIDE-OUT.

5. AIR INTAKE (ILLUSTRATED BELOW).

6.AIR EXHAUST (ILLUSTRATED BELOW).

9 1/2” FACIA ENCLOSURE

13” MINIMUM AIR INTAKE SPACE

15” MINIMUM MAINTENANCE ACCESS SPACE

9 1/2”

19” MINIMUM AIR EXHAUST SPACE

13” MINIMUM

AIR

INTAKE SPACE

32”

MINIMUM MAINTENANCE

 

 

ACCESS SPACE

10 1/2” MIN. AIR EXHAUST SPACE

R

888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com

6

Image 6
Contents Model DO4837R 50 1/8L x 28 5/8D x 37 1/4H Model DO3637R Model DO4837R 38 1/8L x 28 5/8D x 37 1/4H38 1/8L x 28 5/8D x 61 1/8H 50 1/8L x 28 5/8D x 61 1/8HTable of Contents Overview and Warnings Customer Cabinet Provisions Customer Cabinet ProvisionsService Top Cutout Dimensions Clearance Dimensions Clearance and AIR FlowVenting Instructions for AIR Intake / Exhaust DO3637R 2 Facia EnclosureVenting Instructions for AIR Intake / Exhaust DO4837R Page Installation Display Case SetupSeal Upper Display Case to Base Temperature Settings START-UP and OperationCase Start-Up Shelf Assembly Removal Maintenance FundamentalsAdjustable Shelf Light FixturesEvaporator Coil Fans Access and Removal Light Ballast AccessRemoving Rear Doors and Perforated Acrylic Plenum Removing the Rear Doors Removing Perforated Acrylic PlenumTemperature Control Module Refrigeration FundamentalsRefrigeration SLIDE-OUT Exploded Pictorial Technical Information Sheet Model DO3637R Technical Information Sheet Model DO4837R Technical Information Sheet Model DO3623R Technical Information Sheet Model DO4823R Troubleshooting Alarm Going Off, CPC ESC3 Cleaning Schedule Daily Weekly Monthly TaskCPC Controller Overview Compressor Power On DelayCompressor Safety Cycle Controller OverviewCPC ESC3 Controller Operation Indications on the DisplayChanging Other Set Points Viewing and Changing the Temperature Set PointCPC ESC3 SET Point Changing Instructions To change User set pointsWarranty Technical Service