INSTALLATION

1. Remove Case From Skid

Caution: Case must always remain supported or center of gravity may allow case to fall. Slide to rear of skid and tip backward off skid while maintaining support. See illustration below.

2. Display Case Setup

SCC® Service Drop-In Refrigerated Merchan-

diser Case consists of two sections: The Upper

Display Case and Drop-In Refrigerated Section.

As both sections make up one conjoined unit, it

is both large and heavy. A team effort is re-

quired for lowering Case into the Customer Sup-

 

 

 

 

 

 

 

 

 

ld

 

 

 

 

 

 

 

 

 

o

 

 

 

 

 

lyH

 

 

 

 

 

m

 

 

 

 

 

 

 

f

 

ir

 

 

 

 

 

 

 

 

 

 

F

 

 

 

 

 

 

 

r

o

 

 

 

 

 

 

 

 

a

 

 

 

 

 

 

 

 

e

 

 

 

e

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

il

 

 

 

 

 

 

 

 

 

 

h

 

 

 

 

 

 

eW

 

 

 

 

 

s

 

 

 

 

 

 

 

 

 

a

 

 

 

 

 

 

 

 

g

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in

 

 

 

 

 

 

 

 

 

lid

 

ff

 

 

 

 

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

eO

 

 

 

 

 

 

 

 

s

 

 

 

 

 

 

 

 

 

a

 

 

 

id

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

k

 

 

 

 

 

 

 

mS

 

 

 

 

 

 

ro

 

 

 

 

 

 

F

 

 

 

 

 

 

 

Drop-In

Refrigerated

Section

Upper

Display

Case

Slide

Skid

Out

plied Base.

After lowering into Base, adjust into position al-

lowing Case to gingerly rest on Counter Top

without marring.

3. Seal Upper Display Case to Base

NSF® Listed Industrial Grade Silicone Seal- ant is recommended.

Clip tip to allow approximately 1/8” to 3/16” diameter hole.

Beginning at case rear, run a consis- tent, solid bead of silicone around entire perimeter.

Seal

Seal

Along

Along

Here

Here

 

 

 

 

 

 

 

 

 

r

 

 

 

 

 

 

 

e

 

 

 

 

 

m

 

 

 

 

o

 

 

 

 

 

t

 

 

 

 

 

 

s

 

 

 

 

 

 

u

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

d

 

 

 

 

 

 

 

e

 

 

 

 

 

 

li

 

 

 

 

 

p

 

 

 

 

p

 

 

 

 

 

u

 

 

 

 

e

S

 

 

 

 

 

 

 

 

 

 

 

s

 

 

 

 

 

a

 

 

 

 

B

 

 

 

 

R

888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com

9

Image 9
Contents 38 1/8L x 28 5/8D x 61 1/8H Model DO3637R Model DO4837R 38 1/8L x 28 5/8D x 37 1/4HModel DO4837R 50 1/8L x 28 5/8D x 37 1/4H 50 1/8L x 28 5/8D x 61 1/8HTable of Contents Overview and Warnings Customer Cabinet Provisions Customer Cabinet ProvisionsClearance and AIR Flow Service Top Cutout Dimensions Clearance Dimensions2 Facia Enclosure Venting Instructions for AIR Intake / Exhaust DO3637RVenting Instructions for AIR Intake / Exhaust DO4837R Page Installation Display Case SetupSeal Upper Display Case to Base Temperature Settings START-UP and OperationCase Start-Up Adjustable Shelf Maintenance FundamentalsShelf Assembly Removal Light FixturesEvaporator Coil Fans Access and Removal Light Ballast AccessRemoving Rear Doors and Perforated Acrylic Plenum Removing Perforated Acrylic Plenum Removing the Rear DoorsRefrigeration Fundamentals Temperature Control ModuleRefrigeration SLIDE-OUT Exploded Pictorial Technical Information Sheet Model DO3637R Technical Information Sheet Model DO4837R Technical Information Sheet Model DO3623R Technical Information Sheet Model DO4823R Troubleshooting Alarm Going Off, CPC ESC3 Daily Weekly Monthly Task Cleaning ScheduleCompressor Safety Cycle Compressor Power On DelayCPC Controller Overview Controller OverviewIndications on the Display CPC ESC3 Controller OperationCPC ESC3 SET Point Changing Instructions Viewing and Changing the Temperature Set PointChanging Other Set Points To change User set pointsWarranty Technical Service