Impulse dimensions Model DO3637R Model DO4837R 38 1/8L x 28 5/8D x 37 1/4H, 38 1/8L x 8D x

Page 1

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION &

OPERATING MANUAL PN 99574

SERVICOPEN EFRIGERATEDDROP-IN REFRIGERATEDSELF-SERVICEMERCHANDISER

 

 

Model DO3637R

 

 

 

Model DO4837R

 

 

 

 

 

 

 

 

 

 

Model DO3637R

38 1/8”L x 28 5/8”D x 37 1/4”H

(Upper Display Case Only)

 

38 1/8”L x 28 5/8”D x 61 1/8”H

(Upper Display Case + Drop-In Refrigeration Unit)

Model DO4837R

50 1/8”L x 28 5/8”D x 37 1/4”H

(Upper Display Case Only)

 

50 1/8”L x 28 5/8”D x 61 1/8”H

(Upper Display Case + Drop-In Refrigeration Unit)

Model DO3623R

38 1/8”L x 28

5/8”D x 23 1/4”H

(Upper Display Case Only)

 

38 1/8”L x 28

5/8”D x 47

1/8”H

(Upper Display Case + Drop-In Refrigeration Unit)

Model DO4823R

50 1/8”L x 28

5/8”D x 23

1/4”H

(Upper Display Case Only)

 

50 1/8”L x 28

5/8”D x 47

1/8”H

(Upper Display Case + Drop-In Refrigeration Unit)

Note 1. Internal counter height must be at least 28” for refrigeration and proper air flow space.

Note 2. Model DO3637R & 3623R: Service Top Cutout dimensions must be 27.15” Wide x 36.65” Long (with a minimum 1.42” perimeter) for proper clearance and fit of Drop-In Refrigerated Merchandiser. These combined dimensions require a 30” minimum counter top space for cutout.

Note 3. Model DO4837R & DO23R: Service Top Cutout dimensions must be 27.15” Wide x 48.65” Long (with a minimum 1.42” perimeter) for proper clearance and fit of Drop-In Refrigerated Merchandiser. These combined dimensions require a 30” minimum counter top space for cutout.

R

888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com

L:\Inst & Oper Man\Oasis\DO(L)37R, DO(L)23R Operr Man 99574.pub

Rev F Date: 11.2.2006

Image 1
Contents 38 1/8L x 28 5/8D x 61 1/8H Model DO3637R Model DO4837R 38 1/8L x 28 5/8D x 37 1/4HModel DO4837R 50 1/8L x 28 5/8D x 37 1/4H 50 1/8L x 28 5/8D x 61 1/8HTable of Contents Overview and Warnings Customer Cabinet Provisions Customer Cabinet ProvisionsClearance and AIR Flow Service Top Cutout Dimensions Clearance Dimensions2 Facia Enclosure Venting Instructions for AIR Intake / Exhaust DO3637RVenting Instructions for AIR Intake / Exhaust DO4837R Page Display Case Setup InstallationSeal Upper Display Case to Base START-UP and Operation Temperature SettingsCase Start-Up Adjustable Shelf Maintenance FundamentalsShelf Assembly Removal Light FixturesLight Ballast Access Evaporator Coil Fans Access and RemovalRemoving Rear Doors and Perforated Acrylic Plenum Removing Perforated Acrylic Plenum Removing the Rear DoorsRefrigeration Fundamentals Temperature Control ModuleRefrigeration SLIDE-OUT Exploded Pictorial Technical Information Sheet Model DO3637R Technical Information Sheet Model DO4837R Technical Information Sheet Model DO3623R Technical Information Sheet Model DO4823R Troubleshooting Alarm Going Off, CPC ESC3 Daily Weekly Monthly Task Cleaning ScheduleCompressor Safety Cycle Compressor Power On DelayCPC Controller Overview Controller OverviewIndications on the Display CPC ESC3 Controller OperationCPC ESC3 SET Point Changing Instructions Viewing and Changing the Temperature Set PointChanging Other Set Points To change User set pointsWarranty Technical Service