U-Line U-2175RCB-02 manual Electrical Specifications, Cut-Out Dimensions, Prepare Site, Series

Page 5

3 Prepare Site

Your U-Line product has been designed for either free-standing or built-in installation. When built-in, your unit does not require additional air space for top, sides, or rear. However, the front grille must NOT be obstructed and clearance is required for an electrical connection in the rear.

NOTICE

• Unit can NOT be installed behind a closed cabinet door.

Electrical Specifications

!WARNING

SHOCK HAZARD — Electrical Grounding Required.

Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.

Never use an extension cord to connect power to the unit.

NOTICE

Electrical installation must observe all state and local codes. This unit requires connection to a grounded (three- prong), polarized receptacle that has been placed by a qualified electrician.

The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit breaker is recommended. GFCI (ground fault circuit interrupter) is usually not required for fixed location appliances and is not recommended for your unit because a GFCI could be prone to nuisance tripping. However, be sure to consult your local codes.

See below for recommended receptacle location.

Cut-Out Dimensions

2115 Series

Follow the cut-out drawing. The 15-1/4" width allows 1/4" for ease in installation and removal of the unit. 24" is the cabinet depth in most installations.

34-1/8"

24”

to

 

35"

7"

 

1-1/2"

15-1/4"

2175 Series

Follow the cut-out drawing The 24-1/4" width allows 1/4" for ease in installation and removal of the unit. 24" is the cabinet depth in most installations.

24"

34-1/4"

to7"

35-1/8"

4"

24-1/4"

2275 Series

Follow the cut-out drawing The 24-1/4" width allows 1/4" for ease in installation and removal of the unit. 24" is the cabinet depth in most installations.

24"

7"

1-1/2"

24-1/4"

u-line.com

3

Image 5
Contents Installation Guide Table of Contents Safety Precautions Safety Alert DefinitionsGeneral Precautions Product Registration Models Covered Exterior CleaningTools / Material Required Inspect & PlanCut-Out Dimensions Electrical SpecificationsPrepare Site Series2115R Series 2115WC / 2115WCOL Series 21175RC/RCG/RF Series Product Dimensions2175WCC Series 2175BEVC SeriesSide-By-Side Installation Door Swing DimensionsPower Supply Other Site RequirementsTo align and adjust the door Door Alignment and AdjustmentDoor Reversability Doors Self-ClosingReversing Black or White Doors Reinstall hinge to bottom oppositeRemove Door Remove hole plugsReversing Stainless Steel Glass Doors Pull Frame Away Push Glass Remove existing bottom hinge Staining and final finish application Wood Trim FinishingFinal finish-only application To insert a rack in the cabinetPanel Dimensions Door Panel InstallationDoor Panel Installation Custom 1/4 Thick Door Panel InsertGrille Overlay InstallationWood Grille Overlay PreparationGrille Overlay Dimensions 24 Inch Models Grille Overlay Dimensions 15 Inch Models Frame Preparation Overlay Frame2115WCOL 2175WCCOL & 2175BEVCOL Models Only Thickness of the overlay panel must be 3/4Attaching the Overlay Panel Prepare the New Overlay PanelDoor closers Assembling Door to CabinetInstallation InstallationInstallation Troubleshooting Leveling InformationDESIGNED, Engineered and Assembled in WISCONSIN, USA