U-Line U-2175RCW-00 Other Site Requirements, Door Swing Dimensions, Side-By-Side Installation

Page 8

5 Door Swing Dimensions

2175WC Models

2115R Models

Wall

Wall

1/4" Min.

2" Min.

21"

21"

90

Door Swing

Wall

2" Min.

21"

25-1/2"

90

Door Swing

Wall

21"

25-1/2"

16-1/2"

16-1/2"

90

90

Door Swing

Door Swing

Black and White Models

Stainless Models

2115WC Models

Wall

Wall

1/4" Min.

2" Min.

21"

21"

16-1/2"

16-1/2"

90

90

Door Swing

Door Swing

Black, White and Wood Overlay

Stainless Steel

2175R(F) & 2275WC Models

Wall

Wall

1/4" Min.

2" Min.

21"

21"

25-1/2"

25-1/2"

90

90

Door Swing

Door Swing

Black and White

Stainless Steel

2175BEV

Wall

Wall

1/4" Min.

2" Min.

21"

21"

25-1/2"

25-1/2"

90

90

Door Swing

Door Swing

Wood Overlay

Stainless Steel

Black, White and Wood Overlay

Stainless Steel

Units have a zero clearance for the door to open 90°. Stainless Steel models require 2-1/8" door clearance to accommodate the handle if installed next to a wall.

Other Site Requirements

Side-By-Side Installation

For a complete refreshment center, install two units side by side:

Cut-out width for a side-by-side installation is the total of the widths listed under Cut-Out Dimensions in each unit’s Installation Guide.

No trim kit is required. However, 1/4-inch space needs to be maintained between the units to ensure unobstructed door swing.

Units must operate from separate, properly grounded electrical receptacles placed according to each unit’s Electrical Specifications Requirements

Power Supply

The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A circuit (normal household current). See Electrical Specifications.

Environmental Requirements

The units are designed to operate between 50°F (10°C) and 100°F (37°C). High ambient temperatures (100°F [37°C] or higher) may reduce the unit’s ability to reach low temperatures and may also reduce the ice production rate for those models with icemakers.

If the ambient temperature is expected to drop below 45°F (7°C), drain all water from the unit to prevent freezing damage, which is not covered by the warranty.

For best performance, keep the unit out of direct sunlight and away from heat generating equipment.

In climates where high humidity and dew points are present, condensation may appear on outside surfaces. This is considered normal. The condensation will evaporate when the humidity drops.

2115RSOD & 2175SOD Models: For best performance and life outdoors, place under a counter or provide shelter of some kind.

6

u-line.com

Image 8
Contents Installation Guide Table of Contents Safety Precautions Safety Alert DefinitionsGeneral Precautions Exterior Cleaning Product Registration Models CoveredTools / Material Required Inspect & PlanElectrical Specifications Cut-Out DimensionsPrepare Site SeriesProduct Dimensions 2115R Series 2115WC / 2115WCOL Series 21175RC/RCG/RF Series2175BEVC Series 2175WCC SeriesDoor Swing Dimensions Side-By-Side InstallationPower Supply Other Site RequirementsDoor Alignment and Adjustment To align and adjust the doorDoor Reversability Doors Self-ClosingReinstall hinge to bottom opposite Reversing Black or White DoorsRemove Door Remove hole plugsReversing Stainless Steel Glass Doors Pull Frame Away Push Glass Remove existing bottom hinge Wood Trim Finishing Staining and final finish applicationFinal finish-only application To insert a rack in the cabinetDoor Panel Installation Panel DimensionsDoor Panel Installation Custom 1/4 Thick Door Panel InsertInstallation Grille OverlayWood Grille Overlay PreparationGrille Overlay Dimensions 24 Inch Models Grille Overlay Dimensions 15 Inch Models Overlay Frame Frame Preparation2115WCOL 2175WCCOL & 2175BEVCOL Models Only Thickness of the overlay panel must be 3/4Prepare the New Overlay Panel Attaching the Overlay PanelAssembling Door to Cabinet Door closersInstallation InstallationInstallation Troubleshooting Leveling InformationDESIGNED, Engineered and Assembled in WISCONSIN, USA
Related manuals
Manual 28 pages 41.87 Kb