Maintenance
Proper maintenance of your
Defrosting
WARNING
DO NOT use any type of electrical heating device, ice pick, knife or other sharp instrument to defrost; this could damage the inner lining or refrigeration system and void the warranty.
Condenser Cleaning
Interval - Every Three Months
To maintain operational efficiency, keep the front grille free of dust and lint and clean the condenser every three months. Depending on environmental conditions, more or less frequent cleaning may be necessary.
WARNING
Disconnect electric power to the unit before cleaning the condenser.
To remove and replace the grille for access to the condenser fins, follow this procedure:
1
2 | ULIN_0203_A |
Figure 9
1.Disconnect electrical power to the unit.
2.Loosen two screws (Figure 9, 1) completely.
NOTE: Screws are held in the grille by
3. Remove the grille.
WARNING
DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.
CAUTION
DO NOT use any type of cleaner on the condenser unit.
4.Clean the condenser coil (Figure 9, 2) using a soft brush with a “combing” action or vacuum cleaner. Do not touch the condenser coil.
5.Position the grille to align the mounting screws with the holes in the cabinet.
6.Secure, but do not
7.Reconnect power to the unit.
Ice Maker Maintenance
Inlet Screen
Interval - Every Twelve Months
The solenoid valve inlet screen must be cleaned at least once each year as follows:
1.Shut off the water at the main supply valve.
2.Pull the unit out to access the back panel.
3.Disconnect electrical power to the unit.
2
1
ULIN_0054_A
Figure 10
4.Disconnect the hose connector (Figure 10, 1) from the water solenoid valve (Figure 10, 2).
5.DO NOT remove the inlet screen from the water solenoid valve. Use a tooth brush to gently clean any sediment from the inlet screen.
6.
7.Open the water main supply valve and check for leakage at the water hose connection. Ensure that the water supply line is not kinked.
8.Reconnect power to the unit before
12 | CO2175FF, 2175RF |