2. POSITIONING OF HOB

The following operation requires building and/or carpentry work so must be carried out by a competent tradesman.

Installation can be carried out on various materials such as masonry, metal, solid wood or plastic laminated wood as long as they are heat resistant (T 90°C).

Never use silicone or other insulating products when installing the appliance; use only the rubber gasket provided.

2.1.1 Attachment to support structure

Create an opening with the dimensions shown in the figure in the top surface of the counter, keeping a minimum distance of 50 mm from the rear border.

This appliance can therefore be mounted against walls higher than the work surface on condition that a certain distance “X” be kept between the appliance and the wall as shown in the figure so as to avoid damage from overheating.

Make sure there is a minimum of 750 mm between the hot plate flames and any shelf that may be installed directly above them.

Accurately position the gasket provided all around the outer edge of the hole in the top surface as shown in the figures below, pressing it down so as to make it adhere properly. For measurements, refer to the figure depending on the hob model to be installed, bearing in mind that in both models the front and rear sides must skim the hole. Secure the hob to the counter with brackets A (supplied). Carefully trim any excess from border B of the gasket. The distances in the following drawing refer to the hole on the inner side of the gasket.

24

Image 4
Contents Contents Introduction 1. INSTRUCTIONS FOR SAFE AND PROPER USENEVER UNPLUG BY PULLING ON THE CABLE NEVER ATTEMPT TO REPAIR THE APPLIANCEIntroduction THE PLATE ON THE CASING MUST NOT BE REMOVED2. POSITIONING OF HOB Instructions for the installer2.1.1 Attachment to support structure Instructions for the installer Instructions for the installer 3. ELECTRICAL CONNECTIONplate for any reason 4. GAS CONNECTION Instructions for the installerInstructions for the installer 4.1 Connection to LPG4.2 Ventilation of rooms 4.3 Discharge of combustion productsInstructions for the installer 5. ADAPTATION TO DIFFERENT TYPES OF GAS5.1 Removing the hob Instructions for the installer 5.2 Regulation for LPGRated BurnerheatingLPG - G30/G31 28/37 mbar capacity kW5.3 Regulation for G25/25 mbar Instructions for the installer5.4Regulation of primary air 6. FINAL OPERATIONS Instructions for the installer6.1Regulation of minimum for natural gas 6.2 Regulation of minimum for LPGInstructions for the installer 6.3 Arrangement of burners on hob6.4 Lubrication of gas taps This must be done by a qualified technician7. USING THE HOB Instructions for the user7.2 Practical advice for using the burners 7.4 Using a griddle plateInstructions for the user 7.3 Diameter of containers7.5.2 Using the electric elements Instructions for the user8. CLEANING AND MAINTENANCE 8.1 Cleaning8.1.1 Regular daily cleaning of the hob Instructions for the user8.2 Cleaning of cooking hob components 8.2.1 Ignition plugs and safety devicesInstructions for the user 8.2.2 The electric element