Smeg CIR574X Final Operations, Adjustment for natural gas, Adjustment of minimum for natural gas

Page 12
5.3 Adjustment for natural gas

Instructions for the installer

5.3 Adjustment for natural gas

The hob has been adjusted for natural gas at a pressure of 1.0kPa.

To allow the unit to work back with this type of gas, after it has been adjusted for LPG, perform the same operations described in paragraph “5.2 Adjustment for LPG”, but refer to the following table for the proper injectors.

 

 

 

 

 

 

NG – 1.0 kPa

 

 

 

 

Burner (*)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal gas

 

 

Injector

 

 

 

 

 

 

 

 

consumption

 

 

(mm)

 

 

 

 

 

 

 

 

(MJ/h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary (1)

 

 

4.8

 

 

0.98

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi rapid (2)

 

 

6.0

 

 

1.10

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid (6)

 

 

11.5

 

 

1.50

 

 

 

 

 

 

 

 

 

 

 

 

 

Rapid (3)

 

 

12.2

 

 

1.55

 

 

 

 

 

 

 

 

 

 

 

 

 

Wok (4)

 

 

15.0

 

 

1.70

 

 

 

Wok (dual control) (5)

 

 

 

 

15.0

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outer

 

 

11.5

 

 

1.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inner

 

 

3.5

 

 

0.85

 

 

(*) For burner reference numbers, see page 15.

 

 

 

 

 

 

6. FINAL OPERATIONS

Having carried out the above adjustments, reassemble the appliance following, backwards, the instructions in paragraph “5.1 Removing the hob”.

6.1 Adjustment of minimum for natural gas

Light the burner and take it to the minimum 6. FINAL OPERATIONS. Remove the gas tap knob and turn the adjustment screw inside or at the side of the tap shaft (depending on the model) until there is a regular minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.

14

Image 12
Contents Contents Introduction 1. INSTRUCTIONS FOR SAFE AND PROPER USENEVER UNPLUG BY PULLING ON THE CABLE NEVER ATTEMPT TO REPAIR THE APPLIANCETHE PLATE ON THE CASING MUST NOT BE REMOVED Instructions for the installer 2. POSITIONING OF THE HOB2.1 Attachment to support structure 2.2Clearance above and around domestic appliances Extract from AS560130 CM 70 CM HOB HOB REQUIREMENTS NOTES2.3 Room ventilation 2.4 Discharge of combustion products3. GAS CONNECTION 4. ELECTRICAL CONNECTION 5. ADAPTATION TO DIFFERENT TYPES OF GAS 5.1 Removing the hob5.2 Adjustment for LPG Burner5.3 Adjustment for natural gas 6.1 Adjustment of minimum for natural gas6. FINAL OPERATIONS 6.2 Arrangement of burners on the hob 6.3 Lubrication of gas tapsBurners 7. USING THE HOB Instructions for the user7.1 Ignition of the burners 7.2Practical advice for using the burners 7.3Diameter of containersBurner Ø min. and max. in cm7.4.2 Using the electric elements 7.4 Electric elements7.4.1 Turning on electric elements To use correctly remember to 8. CLEANING AND MAINTENANCE 8.1 Cleaning8.2 Cleaning of the hob components 8.1.1 Regular daily cleaning of the hob8.3 Preventive maintenance 9. PROBLEMS AND CAUSES PROBLEMCAUSE WHAT TO DO