3. GAS CONNECTION

Instructions for the installer

3. GAS CONNECTION

This appliance is suitable for installation with Natural Gas or ULPG (propane). Refer to page 12 for the relevant burner pressure and appropriate injector sizes. When the appliance is to be connected to Natural Gas then the pressure regulator supplied must be fitted to the gas inlet. A test point (for checking the gas pressure) is supplied either with the regulator or as a separate fitting in the case of ULPG (propane) appliances.

Connection of the appliance to the gas supply must be in accordance with the requirements of AS5601. A ½” BSP connector at the inlet is recommended and the gas supply line to the appliance must be of adequate length to allow sufficient withdrawal of appliance for service or disconnection and be:

1.annealed copper pipe or;

2.flexible hose according to AS/NZ1869 & be at least Class “B”, 10 mm diameter.

The appliance must be installed with provision to allow the gas to be turned off and disconnected for servicing and removal of the appliance as required from the gas supply.

Before the appliance is operated make certain all relevant parts are placed in the correct position.

When the installation is completed the installation connections of appliance will require to be leak tested, the burner operating pressure and flame checked and adjusted.

Warranty service calls do not cover these adjustments!

To check the operating pressure of the appliance it is recommended at least 2 large size burners are used. Ensure appliance is secured to wall when installation is completed.

N.G. The regulator supplied must be fitted to the ½ BSP thread at the rear of the appliance. An approved manual shut-off valve must be installed. The N.G. regulator must be checked and adjusted to 1.0kPa after installation.

ULPG: Can be connected to the inlet fitting directly. The pressure must be checked to ensure it is operating at 2.75kPa. A separate test point fitting must be installed between the piping & the appliance for the pressure to be checked to ensure it is operating at 2.75kPa.

10

Image 8
Contents Contents Introduction 1. INSTRUCTIONS FOR SAFE AND PROPER USENEVER UNPLUG BY PULLING ON THE CABLE NEVER ATTEMPT TO REPAIR THE APPLIANCETHE PLATE ON THE CASING MUST NOT BE REMOVED 2.1 Attachment to support structure Instructions for the installer2. POSITIONING OF THE HOB 30 CM 70 CM HOB HOB 2.2Clearance above and around domestic appliancesExtract from AS5601 REQUIREMENTS NOTES2.3 Room ventilation 2.4 Discharge of combustion products3. GAS CONNECTION 4. ELECTRICAL CONNECTION 5. ADAPTATION TO DIFFERENT TYPES OF GAS 5.1 Removing the hob5.2 Adjustment for LPG Burner6. FINAL OPERATIONS 5.3 Adjustment for natural gas6.1 Adjustment of minimum for natural gas Burners 6.2 Arrangement of burners on the hob6.3 Lubrication of gas taps 7.1 Ignition of the burners 7. USING THE HOBInstructions for the user 7.2Practical advice for using the burners 7.3Diameter of containersBurner Ø min. and max. in cm7.4.1 Turning on electric elements 7.4.2 Using the electric elements7.4 Electric elements To use correctly remember to 8. CLEANING AND MAINTENANCE 8.1 Cleaning8.2 Cleaning of the hob components 8.1.1 Regular daily cleaning of the hob8.3 Preventive maintenance 9. PROBLEMS AND CAUSES PROBLEMCAUSE WHAT TO DO