4. ELECTRICAL CONNECTION

Instructions for the installer

4. ELECTRICAL CONNECTION

Make sure that the voltage and capacity of the power line conform to the data shown on the plate located under the casing. Do not remove this plate for any reason.

The plug on the end of the supply cable and the wall socket must be the same type and conform to the current electrical system regulations. Check that the power line is adequately grounded.

On the power line, install an omnipolar cut-off device with contact cut-off distance greater than or equal to 3 mm, located in an easily accessible position near the unit.

Do not use reducers, adapters or shunts.

If the power cable is replaced, the wire section on the new cable must not be less than 1.0 mm2 (3 x 1.0 cable), keeping in mind that the end to be connected to the hob must have the ground wire (yellow-green) longer by at least 20 mm. Use only H05V2V2-F cable or similar which has a maximum temperature of 90°C. Any replacement needed should be carried out by a specialised technician who should make the mains connections according to the following diagram.

L = brown N = blue

Manual background = yellow-green

The manufacturer will not be liable for any damage to persons or property caused by non-observance of the above instructions or deriving from the tampering of even a single part of the hob.

11

Image 9
Contents Contents 1. INSTRUCTIONS FOR SAFE AND PROPER USE IntroductionNEVER UNPLUG BY PULLING ON THE CABLE NEVER ATTEMPT TO REPAIR THE APPLIANCETHE PLATE ON THE CASING MUST NOT BE REMOVED Instructions for the installer 2. POSITIONING OF THE HOB2.1 Attachment to support structure 2.2Clearance above and around domestic appliances Extract from AS560130 CM 70 CM HOB HOB NOTES REQUIREMENTS2.4 Discharge of combustion products 2.3 Room ventilation3. GAS CONNECTION 4. ELECTRICAL CONNECTION 5.1 Removing the hob 5. ADAPTATION TO DIFFERENT TYPES OF GASBurner 5.2 Adjustment for LPG5.3 Adjustment for natural gas 6.1 Adjustment of minimum for natural gas6. FINAL OPERATIONS 6.2 Arrangement of burners on the hob 6.3 Lubrication of gas tapsBurners 7. USING THE HOB Instructions for the user7.1 Ignition of the burners 7.3Diameter of containers 7.2Practical advice for using the burnersBurner Ø min. and max. in cm7.4.2 Using the electric elements 7.4 Electric elements7.4.1 Turning on electric elements To use correctly remember to 8.1 Cleaning 8. CLEANING AND MAINTENANCE8.2 Cleaning of the hob components 8.1.1 Regular daily cleaning of the hob8.3 Preventive maintenance PROBLEM 9. PROBLEMS AND CAUSESCAUSE WHAT TO DO