2.3 Room ventilation

Instructions for the installer

2.3 Room ventilation

Caution – This hob may only be installed and operated in rooms permanently ventilated in accordance with current regulations. For proper operation of a gas appliance it is essential for the air necessary for combustion of the gas to be able to flow naturally into the room. Air must flow directly into the room through openings in its outside walls. This (these) opening (s) must have a free passage cross-section of at least 100 cm2, or 200 cm2 for appliances not equipped with gas safety device. These openings must be constructed so that they cannot be obstructed indoors or outdoors, and should preferably be close to the floor on the side opposite to the combustion gas discharge point. If it is not possible to make the openings in the room where the cooker is installed, the necessary air may be taken from an adjoining room, proveded it is not a bedroom or a room with fire risk.

2.4 Discharge of combustion products

Discharge of combustion products must be guaranteed by means of hoods connected to a natural draught flue with certain efficiency, or by means of forced aspiration.

An efficient aspiration system requires careful planning by a specialist capable of installing it, respecting the positions and distances prescribed by standards. After installation, the installer must issue a certificate of conformity.

9

Image 7
Contents Contents NEVER ATTEMPT TO REPAIR THE APPLIANCE Introduction1. INSTRUCTIONS FOR SAFE AND PROPER USE NEVER UNPLUG BY PULLING ON THE CABLETHE PLATE ON THE CASING MUST NOT BE REMOVED 2. POSITIONING OF THE HOB Instructions for the installer2.1 Attachment to support structure Extract from AS5601 2.2Clearance above and around domestic appliances30 CM 70 CM HOB HOB NOTES REQUIREMENTS2.4 Discharge of combustion products 2.3 Room ventilation3. GAS CONNECTION 4. ELECTRICAL CONNECTION 5.1 Removing the hob 5. ADAPTATION TO DIFFERENT TYPES OF GASBurner 5.2 Adjustment for LPG6.1 Adjustment of minimum for natural gas 5.3 Adjustment for natural gas6. FINAL OPERATIONS 6.3 Lubrication of gas taps 6.2 Arrangement of burners on the hobBurners Instructions for the user 7. USING THE HOB7.1 Ignition of the burners Ø min. and max. in cm 7.2Practical advice for using the burners7.3Diameter of containers Burner7.4 Electric elements 7.4.2 Using the electric elements7.4.1 Turning on electric elements To use correctly remember to 8.1.1 Regular daily cleaning of the hob 8. CLEANING AND MAINTENANCE8.1 Cleaning 8.2 Cleaning of the hob components8.3 Preventive maintenance WHAT TO DO 9. PROBLEMS AND CAUSESPROBLEM CAUSE