5 ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, disconnect the appliance from the electrical socket.

The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar. For functioning with other types of gas the nozzles must be replaced and the primary air adjusted.

To replace the nozzles and regulate the burners, you have to remove the top as described in the following paragraph.

5.1Removing the hob

1.Remove all the knobs, the grids, the burner caps and the flame- caps;

2.Remove the screws and the nuts A that secure the burner supports;

3.Lift the hob from its seat;

4.Replace the burner nozzles in accordance with the relevant gas table;

5.Regulate the primary air as described in paragraph “5.2 Regulation for LPG”.

29

Image 9
Contents Contents Instructions for Safe and Proper USE IntroductionIntroduction Instructions for the installer Positioning of the HOBAttachment to support structure Instructions for the installer Electrical Connection GAS Connection Connection to LPG Ventilation of roomsDischarge of combustion products Removing the hob Adaptation to Different Types of GASLPG G30/G31 28/37 mbar Regulation for LPGRegulation for natural gas Regulation for town gasTown Gas 110 8 mbar G20 G30/G31 G110 Regulation of primary airFinal Operations Regulation of minimum for natural gasRegulation of minimum for LPG Lubrication of gas taps Arrangement of burners on hobBurners This must be done by a qualified technicianUsing the HOB Instructions for the userIgnition of the burners Using a griddle plate Practical advice for using the burnersDiameter of the pans Burners Min. and max. in cmCleaning Cleaning and MaintenanceRegular daily cleaning of the hob Food stains or residuesCleaning of cooking hob components Ignition plugs and safety devicesCover