Instructions for the installer
17.2 Burner and nozzle characteristics table
| Rated heating |
|
|
|
|
|
Burner | capacity (kW) |
| LPG – G30/G31 28/37 mbar |
| ||
|
|
|
|
| Flowrate |
|
|
| Nozzle | Reduced | Flowrate | ||
|
| diameter 1/ | 1/100 | flowrate | g/h G30 | g/h G31 |
|
| 100 mm | mm | (W) |
|
|
|
|
|
|
| 76 |
|
Auxiliary | 1.05 | 50 | 30 | 400 | 75 | |
Semi rapid | 1.8 | 65 | 33 | 500 | 130 | 128 |
Rapid | 3.0 | 85 | 45 | 800 | 218 | 214 |
Triple crown | 4.0 | 100 | 65 | 1600 | 291 | 286 |
|
|
|
|
|
|
|
Burner | Rated heating |
| NATURAL GAS – G20/G25 20/25 mbar |
| ||
capacity (kW) |
|
| ||||
|
|
|
|
|
| |
|
|
|
|
| ||
|
| Nozzle diameter |
| Reduced flowrate | ||
|
|
| 1/100 mm |
| (W) |
|
|
|
|
|
|
|
|
Auxiliary | 1.0 |
| 72 (X) |
| 400 |
|
Semi rapid | 1.8 |
| 97 (Z) |
| 500 |
|
Rapid | 3.0 |
| 115 (Y) |
| 800 |
|
Triple crown | 4.0 |
| 135 (K) |
| 1600 |
|
|
|
|
|
|
|
|
17.3 Arrangement of the burners on the hob
BURNERS | min. and max. Ø (in cm) | |
1. | Auxiliary | 12 - 14 |
2. | Semi rapid | 16 - 24 |
3. | Rapid | 18 - 26 |
4. | Triple crown | 18 - 26 |
63