Instructions for the installer
4.1 Adjustment of minimum for natural gas
Light the burner and take it to the minimum . Remove the gas tap knob and turn the adjustment screw inside or at the side of the tap shaft (depending on the model) until there is a regular minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.
4.2 Positioning and levelling of the appliance
Having carried out the electricity and gas
4.3Mounting the rear top upstand
•Position the upstand above the top, taking care to align holes A with holes B.
•Secure the upstand to the top by tightening screws C.
13