Wine Storage | 65 |
subzero.com/specs
Side Panels
MODEL ICBWS-30
When planning for side panels with the installation of the model
IMPORTANT NOTE: The use of side panels may change the width of your rough opening.
When installing a model
The side panel will need to be a minimum of 610 mm deep and 13 mm thick. Refer to the illustrations below for side panel dimensions. Routing will be necessary so that the side panel fits flush against the side of the unit.
Handle Hardware
For overlay and integrated models, handle hardware must be provided. Optional stainless steel tubular and pro handles are available through your authorized
The door frame has numerous mounting holes on each side to accommodate handle hardware. Using the pre- drilled holes to attach the handle will provide the best alignment and strength.
IMPORTANT NOTE: Refer to the
610 mm
FRONT
OF SIDE
PANEL
ROUT TO 3 mm
48 mm |
|
|
|
|
|
| 2134 | |
|
|
|
| |||||
25 mm |
|
|
|
| ||||
|
|
|
|
|
|
|
| mm |
25 mm |
|
| 48 mm |
3 mm |
|
13 mm |
|
MAIN | SIDE PANEL |
FRAME | ROUTING |
Routing detail.
102 mm
OPTIONAL
TOE KICK |
|
|
| 67 mm |
|
|
Side panel dimensions.