Traulsen G-Series owner manual VII. f Customer Service Parameters

Page 9

VII. MICROPROCESSOR CONTROL (continued)

VII. f - CUSTOMER SERVICE PARAMETERS:

Listed below are the available parameters in the order they appear, using the down arrow key on the controller. You can use either the up or down arrow keys to scroll through the options.

Thermostat Set Point High*

Thermostat Set Point Low

Temperature Scale

Time (24-hour clock)

Date (month - day - year)

Daylight Savings

Start Manual Defrost

Defrost Lockout 1

VII. g - ADJUSTING THE THERMOSTAT SET POINT HIGH:

Defrost Lockout 2

Defrost Lockout 3

Defrost Lockout 4

Room Temperature Offset

Evaporator Coil Sensor

This parameter sets the high point of the desired cabinet temperature range. Typically, freezers will range from -3°F to 0° F (-19°C to -18°C) and refrigerators will range from 36° F to 40° F (2° C to 4° C) for this parameter setting. This parameter is preset at the factory and does not have to be adjusted unless the customer chooses to do so. Note: Set Point Low and Set Point High cannot be set to the same temperature. There will be at least 1-2 degree difference between the two settings.

Follow the instructions to enter the customer access code on page 7. When the control

display reads Thermostat Set Point High. Press the set button SET .

Use the arrow keys to adjust the temperature to your desired setting. When the display shows the temperature you want press the set button SET .

The display will then read Thermostat Set Point High.

You can use the up or down arrow keys to scroll to the next parameter or wait 30 seconds for the control to return to normal operation.

-8-

Image 9
Contents Traulsen & Co., Inc Serial TAG Table of ContentsII. Receipt Inspection III. InstallationIV. Operation III. InstallationCare & Maintenance VII. Microprocessor Control VI. MISC. OperationsVII. Microprocessor Control You are now in the Customer / Service Parameters VII. f Customer Service Parameters VII. h Adjusting the Thermostat SET Point LOW VII. j Setting the 24-HOUR Clock VII. k Setting the Date Defrost Icon OFF VII. o Adjusting the Room Temperature Offset Find Your Problem Here Remedy VIII. Trouble Shooting GuideStandard Domestic Warranty IX. Warranty InformationOther XI. Parts ListXII. Index Quality Refrigeration