True Manufacturing Company TD-50-18-S-LT Temperature Control Adjustment for High Altitude only

Page 15

True Food Service Equipment, Inc.

MAINTENANCE, CARE & CLEANING

TEMPERATURE CONTROL ADJUSTMENT FOR HIGH ALTITUDE ONLY!

TERMS:

__________ STEP 4 ___________

Cut-out - Temperature sensed by the controller that shuts the compressor off.

Cut-in - Temperature sensed by the controller that turns the compressor on.

REQUIRED TOOLS

Phillips Head Screwdriver

5/64" or 2 mm Allen Wrench

T-7 Torx Wrench

__________ STEP 1 ___________

Unplug the cooler.

__________ STEP 2 ___________

For high elevation installations, it may be necessary to "warm- up" the set points. To make the adjustment, insert the appropriate tool in each adjustment screw and turn 1/4 of a revolution clockwise (to the right). This procedure will adjust both the cut-in and cut-out about 2°F warmer.

__________ STEP 5 ___________

Make sure to reconnect the pink wire to the proper spade terminal when reinstalling.

Remove the screws that secure the temperature control to the inset box.

__________ STEP 3 ___________

Pull out gently from cabinet.

NOTE:

Mechanical temperature

controllers are affected when

functioning at high altitude. The

cut-in and cut-out

temperatures will be colder than

when the controller functions

closer to sea level

Danfoss Temperature Control (High Altitude Adjustment Only!)

Cut-out Adjustment Screw Allen (5/64" or 2 mm) (clockwise for warmer)

Cut-in Adjustment Screw Torx (T-7) (clockwise for warmer)

Compressor Connection (pink)

Compressor Connection (pink)

13

www.truemfg.com

13

Image 15
Contents BAR Equipment Glass Chillers True Food Service Equipment, Inc Safety Precautions Refrigerant Disposal Proper Disposal of the RefrigeratorUSE of Extension Cords Before You Throw Away Your Old Refrigerator or FreezerNorth America Use Only HOW to Connect ElectricityStep Installation / Operation Instructions OwnershipRequired Tools UncratingLocating LevelingTools Required Conductors and Circuits NSF Approved Sealants Sealing Cabinet to FloorPosition Cabinet Step Level CabinetNext Install Draft ARMElectrical Instructions Beer DispensersStartup Install Draft ARMLight Switch Location Replacement PartsStorage and Handling Shelf InstallationHorizontal Bottle Cooler BIN Divider Installation OperationTDD-1 CO2 KNOCK-OUT TemperaturePressure TappingBad Taste Draft Beer ProblemsDanfoss Temperature Control High Altitude Adjustment Only Temperature Control Adjustment for High Altitude onlyDont lay CO2 cylinders flat Dont drop CO2 cylinders Pressure Adjustment on CO2 RegulatorChanging CO2 GAS Cylinder Decreasing PressureCleaning Cleaning BAR SystemCleaning kit purchased from True follow these instructions Prepare SolutionStep MAINTENANCE, Care & Cleaning Cleaning the Condenser CoilDisconnect the electrical power to the unit Remove the louvered grillSaturday 745 a.m. to 1145 a.m. CST Stainless Steel Equipment Care and Cleaning Stainless Steel Equipment Care and Cleaning Light Bulb Replacement IDL Integrated Door Lighting Warranty Information U.S.A. and Canada only