True Manufacturing Company TBB-2, TD-50-18-S-LT, TDD-4, TBB-3G-S Locating, Leveling, Tools Required

Page 7

True Food Service Equipment, Inc.

INSTALLATION / OPERATION INSTRUCTIONS

LOCATING

TOOLS REQUIRED:

Phillips screw driver

3/8” socket or 3/8” wrench

Step 2

A.Use a phillips screw diver and remove four screws from the L-bracket connected the unit to the wood skid (see image 1). Then use a 3/8” socket or wrench and remove the L-bracket from the unit (see image 2).

When lifting unit do not use the countertop as a lifting point. Also remember to leave cabinet upright for 24 hours before plugging

into power source.

B.Remove skid by unscrewing all base rail anchor brackets. Place skid to the side.

C.Carefully upright cabinet.

(Image 1) Removing bracket from skid.

(Image 2) Removing bracket from cabinet.

LEVELING

Step 3

A.Set unit in its final location. Be sure there is adequate ventilation in your room. Under extreme heat conditions, (100°F+, 38°C+), you may want to install an exhaust fan.

Warning

Warranty is void if ventilation is insufficient.

B.Proper leveling of your True cooler is critical to operating success (for non-mobile models). Effective condensate removal and door operation will be effected by leveling.

C.The cooler should be leveled front to back and side to side with a level.

D.Ensure that the drain hose or hoses are positioned in the pan.

E.Free plug and cord from inside the lower rear of the cooler (do not plug in).

F.The unit should be placed close enough to the electrical supply so that extension cords are never used.

Warning

Compressor warranties are void if the unit is more than 7 ft. (2.1m) from plug-in connection or an extension cord is used to connect unit to a power supply.

5

www.truemfg.com

5

Image 7
Contents BAR Equipment Glass Chillers True Food Service Equipment, Inc Safety Precautions Refrigerant Disposal Proper Disposal of the RefrigeratorUSE of Extension Cords Before You Throw Away Your Old Refrigerator or FreezerNorth America Use Only HOW to Connect ElectricityStep Installation / Operation Instructions OwnershipRequired Tools UncratingLeveling LocatingTools Required Conductors and Circuits NSF Approved Sealants Sealing Cabinet to FloorPosition Cabinet Step Level CabinetNext Install Draft ARMElectrical Instructions Beer DispensersStartup Install Draft ARMLight Switch Location Replacement PartsStorage and Handling Shelf InstallationHorizontal Bottle Cooler BIN Divider Installation OperationTDD-1 CO2 KNOCK-OUT TemperaturePressure TappingBad Taste Draft Beer ProblemsDanfoss Temperature Control High Altitude Adjustment Only Temperature Control Adjustment for High Altitude onlyDont lay CO2 cylinders flat Dont drop CO2 cylinders Pressure Adjustment on CO2 RegulatorChanging CO2 GAS Cylinder Decreasing PressureCleaning Cleaning BAR SystemCleaning kit purchased from True follow these instructions Prepare SolutionStep MAINTENANCE, Care & Cleaning Cleaning the Condenser CoilRemove the louvered grill Disconnect the electrical power to the unitSaturday 745 a.m. to 1145 a.m. CST Stainless Steel Equipment Care and Cleaning Stainless Steel Equipment Care and Cleaning Light Bulb Replacement IDL Integrated Door Lighting Warranty Information U.S.A. and Canada only