True Manufacturing Company TCGR-77 Temperature Control Adjustment for High Altitude only, Terms

Page 17

True Food Service Equipment, Inc.

MAINTENANCE, CARE & CLEANING

TEMPERATURE CONTROL ADJUSTMENT FOR HIGH ALTITUDE ONLY!

TERMS:

Cut-out - Temperature sensed by the controller that shuts the compressor off.

Cut-in - Temperature sensed by the controller that turns the compressor on.

TOOLS REQUIRED:

Phillips head screwdriver

5/64" or 2 mm Allen wrench

T-7 Torx wrench

A.Unplug or disconnect power to the cabinet.

B.Remove the screws that secure the tempera- ture control to the inset box, lower right, rear of cabinet.

C.Pull out gently from cabinet.

NOTE

Mechanical temperature controllers are affected when functioning at high altitude. The Cut-in and cut-out temperatures will be colder than when the controller functions closer to sea level.

D.For high elevation installations, it may be nec- essary to "warm-up" the set points. To make the adjustment, insert the appropriate tool in each adjustment screw and turn 1/4 of a revo- lution clockwise (to the right). This procedure will adjust both the cut-in and cut-out about 2°F warmer.

E.Make sure to reconnect the wire to proper spade terminal when reinstalling.

Compressor Connection

DANFOSS TEMPERATURE CONTROL

Cut-out Adjustment Screw Allen (5/64" or 2 mm) (clockwise for warmer)

Cut-in Adjustment Screw Torx (T-7)

(clockwise for warmer)

Compressor Connection (double terminal)

4

3

15

www.truemfg.com

15

Image 17
Contents Curved Glass Display Cases Page Safety Precautions USE of Extension Cords Proper Disposal of the Display CaseFor models with standard power cord HOW to Connect ElectricityRequired Tools Installation / Operation Instructions OwnershipUncrating True is not responsible for damage incurred during shipmentLocating Warranty is void if ventilation is insufficientLeveling Tools RequiredElectrical Instructions Conductors and Circuits Startup Replacement PartsRecommendation Refrigerated Curved Glass Display CasesShelf Installation Shelving Installation Refrigerated BakeryFor lights to work. If less than Attached caps are plugged intoShelving Installation Cold Deli Castor Installation Tools Required Optional Installing Optional CastorsRefer to image 1 for placement of Formica panels Optional Installing Optional Formica KITFormica KIT Installation Formica KIT Components Optional Sealing Cabinet to Floor Cabinet CleaningInterior TOP Bulb Replacement Light Bulb ReplacementShelf Mounted Bulb Replacement Terms Temperature Control Adjustment for High Altitude onlyDanfoss Temperature Control Condenser Cleaning Tools Required Cleaning the Condenser CoilImportant Warranty Information Stainless Steel Equipment Care and Cleaning Stainless Steel Equipment Care and Cleaning ONE Year Parts & Labor Warranty