True Manufacturing Company TCGR-77 installation manual Locating, Leveling, Tools Required

Page 7

True Food Service Equipment, Inc.

INSTALLATION / OPERATION INSTRUCTIONS

LOCATING

TOOLS REQUIRED:

Phillips screw driver

3/8” (9.5 mm) socket or 3/8” (9.5 mm) wrench

Step 2

A.Use a Phillips screw diver and remove four screws from the L-bracket connected the unit to the wood skid (image 1). Then use a 3/8” (9.5 mm) socket or wrench and remove the L-brack- et from the unit (image 2).

To avoid damage to glass DO NOT lay cabinet on its side or back when removing skid, installing leg levelers, cleaning, etc.

B.Lift up from the base and walk unit off the skid and set in final location.

1

Removing bracket from skid.

2

C.Unblock doors, (free plastic wedges, blue foam and tape. Remove fiberglass tape securing glass. Remove components: (shelves, brackets, etc.) from inside cabinet.

LEVELING

Removing bracket from cabinet.

Step 3

A.Set unit in its final location. Be sure there is ade- quate ventilation in your room. Under extreme heat conditions, (100°F+, 38°C+), you may want to install an exhaust fan.

Warning

Warranty is void if ventilation is insufficient.

B.Proper leveling of your True unit is critical to operating success (for non-mobile models). Effective condensate removal and door operation will be effected by leveling.

Warning

Display case must be leveled accurately to ensure front glass door seals properly.

C.The unit should be leveled front to back and side to side with a level. Place the level in the interior floor of the unit and check all four sides.

D.If the cabinet is not level adjust leg levelers by first relieving weight to leveler and adjusting by either hand or wrench. Repeat with all leg level- ers until cabinet is level in all directions.

E.Ensure that the drain hose or hoses are posi- tioned in the pan.

F.Models with power cord: Free plug and cord from inside the lower rear of the cooler (do not plug in).

G.Models with power cord: The unit should be placed close enough to the electrical supply so that extension cords are never used.

Warning

Compressor warranties are void if the unit is more than 9 ft. (3 m) from plug-in connection or an exten- sion cord is used to connect unit to a power supply.

5

www.truemfg.com

5

Image 7
Contents Curved Glass Display Cases Page Safety Precautions USE of Extension Cords Proper Disposal of the Display CaseFor models with standard power cord HOW to Connect ElectricityTrue is not responsible for damage incurred during shipment Installation / Operation Instructions OwnershipRequired Tools UncratingTools Required Warranty is void if ventilation is insufficientLocating LevelingElectrical Instructions Conductors and Circuits Refrigerated Curved Glass Display Cases Replacement PartsStartup RecommendationAttached caps are plugged into Shelving Installation Refrigerated BakeryShelf Installation For lights to work. If less thanShelving Installation Cold Deli Castor Installation Tools Required Optional Installing Optional CastorsFormica KIT Installation Formica KIT Components Optional Installing Optional Formica KITRefer to image 1 for placement of Formica panels Optional Sealing Cabinet to Floor Cabinet CleaningShelf Mounted Bulb Replacement Light Bulb ReplacementInterior TOP Bulb Replacement Danfoss Temperature Control Temperature Control Adjustment for High Altitude onlyTerms Condenser Cleaning Tools Required Cleaning the Condenser CoilImportant Warranty Information Stainless Steel Equipment Care and Cleaning Stainless Steel Equipment Care and Cleaning ONE Year Parts & Labor Warranty