True Manufacturing Company TCGR-77 Light Bulb Replacement, Shelf Mounted Bulb Replacement

Page 16

True Food Service Equipment, Inc.

MAINTENANCE, CARE & CLEANING

LIGHT BULB REPLACEMENT

SHELF MOUNTED BULB REPLACEMENT:

WARNING

When replacing a light bulb make sure power to the unit is either turned off or unplugged.

A.Unplug the light assembly from the receptacle on the interior side wall. Remove shelf and light assembly from cabinet.

B.Remove the lampshield by gently squeezing the sides together and rotating out (image 1).

C.Remove bulb from the corded end of assembly by holding the bulb and gently pulling up on spring loaded lampholder which will allow enough clearance to remove bulb (image 2).

NOTE

All spring loaded lampholders are located on the left side of the cabinet as you face the front.

NOTE

Please be aware of your local ordinances for dis- posal of old florescent bulbs. These bulbs should be disposed of in a safe and proper manner.

D.Install new bulb using spring loaded lamp- holder.

E.Reinstall light assembly and shelf. Plug cord into side wall receptacle.

INTERIOR TOP BULB REPLACEMENT:

WARNING

When replacing a light bulb make sure power to the unit is either turned off or unplugged.

A.Remove the lampshield by gently squeezing the sides together and rotating out (image 3).

B.Remove bulb by gently pushing bulb back into spring loaded lampholder which will allow enough clearance to remove bulb (image 4).

C.Install new bulb using spring loaded lamp- holder.

D.Reinstall light lampshield by sliding rear "U" channel of lampshield over metal bracket and gently squeezing lampshield to fit front "U" channel over front metal bracket (images 5-6).

E.Image 7 shows assembly properly installed.

 

 

1

 

2

 

 

 

 

Squeeze lampshield and

 

Remove bulb by gently

rotate out.

 

pulling up on spring

 

 

 

loaded lampholder.

 

 

 

3

 

 

 

4

Squeeze lampshield and

rotate out.Remove bulb by gently pushing bulb into spring loaded lamp- holder.

 

 

 

5

 

6

 

 

 

 

 

Squeeze lampshield "U"

lampshield "U" channel

channel into position

in position over metal

over metal bracket.

bracket.

7

Interior top light assembly properly installed.

14

www.truemfg.com

14

Image 16
Contents Curved Glass Display Cases Page Safety Precautions Proper Disposal of the Display Case USE of Extension CordsHOW to Connect Electricity For models with standard power cordInstallation / Operation Instructions Ownership Required ToolsUncrating True is not responsible for damage incurred during shipmentWarranty is void if ventilation is insufficient LocatingLeveling Tools RequiredElectrical Instructions Conductors and Circuits Replacement Parts StartupRecommendation Refrigerated Curved Glass Display CasesShelving Installation Refrigerated Bakery Shelf InstallationFor lights to work. If less than Attached caps are plugged intoShelving Installation Cold Deli Optional Installing Optional Castors Castor Installation Tools RequiredFormica KIT Installation Formica KIT Components Optional Installing Optional Formica KITRefer to image 1 for placement of Formica panels Cabinet Cleaning Optional Sealing Cabinet to FloorShelf Mounted Bulb Replacement Light Bulb ReplacementInterior TOP Bulb Replacement Danfoss Temperature Control Temperature Control Adjustment for High Altitude onlyTerms Cleaning the Condenser Coil Condenser Cleaning Tools RequiredImportant Warranty Information Stainless Steel Equipment Care and Cleaning Stainless Steel Equipment Care and Cleaning ONE Year Parts & Labor Warranty