True Manufacturing Company TCGDZ-50 Temperature Control Adjustment for High Altitude only, Terms

Page 16

True Food Service Equipment, Inc.

MAINTENANCE, CARE & CLEANING

TEMPERATURE CONTROL ADJUSTMENT FOR HIGH ALTITUDE ONLY!

TERMS:

NOTE

Cut-out - Temperature sensed by the controller

Mechanical temperature controllers are affected

 

that shuts the compressor off.

when functioning at high altitude. The Cut-in and

Cut-in - Temperature sensed by the controller

cut-out temperatures will be colder than when the

controller functions closer to sea level.

 

that turns the compressor on.

 

 

TOOLS REQUIRED:

D. For high elevation installations, it may be nec-

essary to "warm-up" the set points. To make

Phillips head screwdriver

the adjustment, insert the appropriate tool in

5/64" or 2 mm Allen wrench

each adjustment screw and turn 1/4 of a revo-

T-7 Torx wrench

lution clockwise (to the right). This procedure

 

 

A. Unplug or disconnect power to the cabinet.

will adjust both the cut-in and cut-out about

2°F warmer.

B. Remove the screws that secure the tempera-

E. Make sure to reconnect the pink wire to prop-

 

ture control to the inset box, lower right, rear

er spade terminal when reinstalling.

 

 

of cabinet.

C.Pull out gently from cabinet.

DANFOSS TEMPERATURE CONTROL

Compressor Connection (pink)

4

3

Cut-out Adjustment Screw Allen (5/64" or 2 mm) (clockwise for warmer)

Cut-in Adjustment Screw Torx (T-7)

(clockwise for warmer)

Compressor Connection (pink)

(double terminal)

To wire temperature control:

connect one pink wire (either one) to terminal 3 and the other pink wire to terminal 4.

14

www.truemfg.com

14

Image 16
Contents Curved Glass Display Cases True Manufacturing Company, Inc Safety Precautions Proper Disposal of the Display Case USE of Extension CordsFor models with standard power cord Never USE AN Adapter PlugInstallation / Operation Instructions Ownership Required ToolsUncrating True is not responsible for damage incurred during shipmentWarranty is void if ventilation is insufficient LocatingLeveling Tools RequiredElectrical Instructions Conductors and Circuits Startup Replacement PartsRecommendation Shelving Installation Refrigerated Bakery Shelf InstallationFor lights to work. If less than Attached caps are plugged intoOptional Installing Optional Castors Castor Installation Tools RequiredFormica KIT Installation Formica KIT Components Optional Installing Optional Formica KITRefer to image 1 for placement of Formica panels Cabinet Cleaning Optional Sealing Cabinet to FloorShelf Mounted Bulb Replacement Light Bulb ReplacementInterior TOP Bulb Replacement Temperature Control Adjustment for High Altitude only Danfoss Temperature ControlTerms Controller functions closer to sea levelCleaning the Condenser Coil Condenser Cleaning Tools RequiredImportant Warranty Information Stainless Steel Equipment Care and Cleaning Stainless Steel Equipment Care and Cleaning Warranty Information U.S.A. and Canada ONLY! U.S.A