True Manufacturing Company TCGDZ-50 Installation / Operation Instructions Ownership, Uncrating

Page 6

True Food Service Equipment, Inc.

INSTALLATION / OPERATION INSTRUCTIONS

INSTALLATION / OPERATION INSTRUCTIONS

OWNERSHIP

To insure that your unit works properly from the first day, it must be installed properly. We highly recommend a trained mechanic and electrician install your True equipment. The cost of a profes- sional installation is money well spent.

Before you start to install your True unit, carefully inspect it for freight damage. If damage is discov- ered, immediately file a claim with the delivery freight carrier.

True is not responsible for damage incurred during shipment.

REQUIRED TOOLS

• Tin Snips / Band Cutters

3/4" (19 mm) Open-End Wrench

Claw Hammer

Phillips Head Screwdriver

Hex Head Driver

Level

Adjustable Wrench

UNCRATING

Step 1

The following procedure is recommended for uncrating the unit:

A.Cut metal retaining straps securing protective top skid. Remove the outer packaging by pull- ing tri-wall nails from skid. Remove (4) card- board corner pads and dust cover.

B.Inspect for concealed damage. Again, immedi- ately file a claim with the freight carrier if there is damage.

C.Move your display case as close to the final loca- tion as possible before removing the wooden skid.

REMOTE UNITS (This section applies to remotes only!)

Remote cabinets must be ordered as remote. We do not recommend converting a standard self contained to remote system.

All remote cabinets must be hard wired.

Remote cabinets are not available with castors.

All remote cabinets come standard using 404A refrigerant.

All remote units come standard with expansion valve, liquid line solenoid, heated condensate pan, and defrost timer when applicable.

Contact True Technical Service for BTU require- ments.

No wiring necessary between cabinet and con- densing unit.

All remote condensing units purchased from True are 208/230 volts single phase.

If you have any questions regarding this section, please call True at 1 (800) 325-6152.

4

www.truemfg.com

4

Image 6
Contents Curved Glass Display Cases True Manufacturing Company, Inc Safety Precautions Proper Disposal of the Display Case USE of Extension CordsFor models with standard power cord Never USE AN Adapter PlugUncrating Installation / Operation Instructions OwnershipRequired Tools True is not responsible for damage incurred during shipmentLeveling Warranty is void if ventilation is insufficientLocating Tools RequiredElectrical Instructions Conductors and Circuits Replacement Parts StartupRecommendation For lights to work. If less than Shelving Installation Refrigerated BakeryShelf Installation Attached caps are plugged intoOptional Installing Optional Castors Castor Installation Tools RequiredOptional Installing Optional Formica KIT Formica KIT Installation Formica KIT ComponentsRefer to image 1 for placement of Formica panels Cabinet Cleaning Optional Sealing Cabinet to FloorLight Bulb Replacement Shelf Mounted Bulb ReplacementInterior TOP Bulb Replacement Terms Temperature Control Adjustment for High Altitude onlyDanfoss Temperature Control Controller functions closer to sea levelCleaning the Condenser Coil Condenser Cleaning Tools RequiredImportant Warranty Information Stainless Steel Equipment Care and Cleaning Stainless Steel Equipment Care and Cleaning Warranty Information U.S.A. and Canada ONLY! U.S.A