Step 4
A.Before your new unit is connected to a power supply, check the incoming voltage with a volt- meter. If anything less than 100% of the rated voltage for operation is noted, correct immedi- ately.
B.Models equipped with 9 ft. (3 m) power cord must be powered at proper operating voltage at all times.
Refer to cabinet data plate for voltage.
True requires that a sole use circuit be dedicated for the unit.
Warning
For proper performance of refrigerated cabinet an ambient temperature no greater than 75°F (24°C) with a relative humidity of 55% is required.
WARNING
Compressor warranties are void if compressor burns out due to low voltage.
WARNING
Power supply cord ground should not be removed!
NOTE
To reference wiring diagram - Remove lower rear grill. Wiring diagram is positioned on the ballast box inside lower rear of the cabinet.
6 | www.truemfg.com | 6 |