Worth Data Comprehensive Guide to 7000 Series RF Terminal Features and Settings

Page 20

Other Bar Code Options

Storage Tek Label

ON

OFF

2

Labelcode 5

ON

OFF

3

Labelcode 4

ON

OFF

4

Bar Code ID's

ON

OFF

5

The Storage Tek Tape Label code is a proprietary variation of Code 39 code used for the storage of computer data tapes. Enabling the tape label code does not disable reading of Code 128 or Code 39 bar codes.

Labelcode 5 and Labelcode 4 are proprietary bar code types used by Follet.

Bar Code ID’s are characters assigned to each bar code type to identify that particular type of code. These Bar Code IDs can output as prefix to the bar code data to identify what type of bar code you are using. The Bar Code ID’s are assigned as follows:

Bar Code

ID

Bar Code

ID

Bar Code

ID

Bar Code

ID

Codabar

a

2 of 5

f

UPC-E (1)

o

LabelCode 4

y

Code 39

b

Code 128

g

EAN-8

p

LabelCode 5

z

UPC-A

c

Code 93

i

RSS-14

r

 

 

EAN-13

d

MSI

j

StorageTek

s

 

 

I 2of 5

e

UPC-E(0)

n

Plessey

x

 

 

The ID character is transmitted in front of the bar code data.

RS-232 I/O Settings

Baud Rate

Use the 1 key to select the baud rate. The default value is 9600. The available baud rates are 2400, 4800, 9600, 19200, 38400, 57600 and 115200.

Parity

Use the 2 key to select the parity.

The options are None, Even or Odd.

None is generally used with 8 data bits

Even or Odd parity is generally used with 7 data bits.

Data Bits

Use the 3 key to select either 8 or 7 data bits.

XON / XOFF Printer

Setting 4 pertains to use of a serial Printer with your RF Terminal. Use key 4 to enable XON / XOFF if

Image 20
Contents Page Page Table of Contents Introduction DifferencesPage Installation Installation SequenceConnecting the Base Station to a serial port ComponentsBase station channel… Connecting the Base station…Configuring the Base station… Using the RF Terminal keypad… Battery Life IndicatorCharge Battery Hit Any Key Battery too Low to Operate Hit Any Key to Power DownTo change the internal battery Recharging the batteryCharging Battery Please Wait……… Battery Charge CompleteFirmware Uxxx HWyy-Rzz Opening screen can be bypassed upon power up. See ChapterTerminal Menu Functions Installing the RF Terminal Utilities Software Using the Windows 7000 RF Terminal Loader UtilityInstalling the Windows Terminal Loader Utility Windows Demo Programs and RF DLL Programmers LibraryTerminal Eprom Loader Help Uninstall Sign On Setup One Way Mode RF Site Survey RF System SetupUsing the Setup Menu on the RF Terminal RF Configuration RF Terminal IDRF Terminal Channel Security CodeSkip Opening Screens Control Keys OnlyCode 3 of 9 Code Bar Code OptionsAutomatic Check Back UPC-A / EAN-13 Options UPC-E / EAN-8 Options CodeCodabar 5 CodeDataBar / RSS-14 Options MSI and PlesseyCode 93 / Code RS-232 I/O Settings Set Time Set DateDate Format Year OutputSpeaker Settings Laser OptionsLCD Options Nnmm Other SettingsPreamble Settings menu PostambleReset to Factory Default System ToolsCharacters Download FileBase and Relay Setup Using the RF 7000 Configuration UtilityTesting the RF link between base station and host Operational Theory@@*EdataaaaaaaaEOT DataaaaaaaaCRHow the Two-Way RF System works Basic RF System communications…Little more in depth… Here is how it worksHow the One-Way RF System works Can I change a prompt after it has been sent?How Site Survey works Data Received Was Enter Data?Performing a Site Survey Performance IssuesEvaluating your area of planned operation Press Enter When Ready or F1 to Exit Site Testing in Progress Please Wait…………Relay n Cannot be Relay StationsHow Relay Stations work… Determining coverage areas for Base Stations and Relays Is radio traffic contention likely?Relay Installation Before you begin programming… Command without an ID Operator ErrorsFailure Planning Hardware FailuresProgramming for the RF Terminal LOW Level Ascii sequences directlyPlanning Host to Terminal ProgrammingColor Display Programming @Cfnfnfn...\cb= White Where n m @n,m,o,data@1,1,1,ITEM@2,1,1,QTY Page @2,1,1,ENTER Item no Base Station to Host Formats Serial ReplyAddressing a Terminal not SIGNed on Base Station Error FeedbackBase Shut Down Due to Host Logic Error Sequence Error Message Illegal Command?CR @1,1,1,Scan Serial NumberControl Keys for Possible Programming Base Station Initialized MessagePage PromptCOM/ActiveX Concepts ActiveX Object ProgrammingValid valuesNone, Even, Odd Properties ActiveX ObjectValid values True, False Methods ActiveX ObjectColor Codes for Line TerminalParameters line, position, prompt Parameters line, position, prompt, FG, BGParameters line, position, prompt,FG,BG Parameters line, position, prompt, shiftedParameters font, linecount Parameters FGcolor, BGcolor Events ActiveX ObjectData passedterminal, data Terminal Data PassedProgramming Considerations Network Setup PromptNET TCP/IP Active X ControlsClient Utility Server CommunicationsConcepts TCP/IP COM Test For Good CommunicationProblems Properties TCP/IP COMValid values blank or a valid file name Read OnlyParameters basename, channel, terminal, data Parameters basename, channel, terminalParameters basename, channel, terminal, line Parameters basename, channel, terminal, countParameters basename, channel, terminal, msgnum Parameters basename, channelEvents TCP/IP COM Data passedbasename, channelData passedbasename, channel, terminal, data OnTermEndKey Zebra Cameo Printer Portable PrintersCameo and QL 3 Common Information Zebra QL 3 Printer Part Number Description Price/RollWhy Use Voice Messages and Prompts? Tips for Using Voice PromptsAssigning Error Messages Voice Message OperationsDefault Voice Messages Troubleshooting Problems with a new installationChanging the Battery General ConsiderationsTerminal Error Messages MessageMeaning Action Required Message Meaning Action RequiredTroubleshooting specific problems Can’t communicate at allMy response time is poor Im not getting the distance I needRF Terminal Problems Problems reading Bar CodesGet 6 beeps when the RF Terminal powers up Reader wont beep when I try to read bar codesIf you have a problem… Have very poor read rates when scanning bar codesRMA #XXXXXX Channel and Jumper Changes Opening a BaseChanging a Base to a Relay RS-422 Termination JumpersConnecting a Relay Station Setting the Relay IDAdding Relays Channel ChangesRouting the Wiring Correct Routing for WiringRelay Test Plan and Failures Relay Failure Incorrect Routing for WiringRelay Station RS422 Pin-outs Testing the Relay Changing a Relay back to a BaseChanging the Channel on a Relay RS-422 TerminationSerial Pin-outs Base Station to Host Pin-outsF34 DB25 Null Modem Cable F36 DB9 Straight CableFirmware Upgrades Terminal Firmware UpgradesRelay Station RS422 Pin-outs Normal Firmware Download for a TerminalCode 39 Specifications Base Station Firmware upgradesFailsafe Firmware Download for a Terminal C39Code 39 Advanced Features and Functions Mod 43 Check CharacterMod 43 Check character calculation for Code Value 22 is the Check CharacterAccumulate Mode Full Ascii Extension to CodeCode 93 Specifications Clear EnterCodabar Specifications Code 128 SpecificationsA12345b Codabar start/stop transmissionInterleaved 2 of 5 Code Specifications UCC-128 Shipping Container CodeUPC / EAN Specifications Isbn Specifications Supplemental codesUPC/EAN checksum character MSI/Plessey Specifications How to scan a bar code Laser ScannersLaser Options Aiming the Laser DotAscii Code Equivalent Table BEL

7000 specifications

The Worth Data 7000 is an advanced data collection and management device designed for various applications, including inventory control, asset tracking, and point-of-sale transactions. This versatile handheld device excels in environments requiring efficiency and reliability, making it a popular choice for businesses looking to optimize their operational workflows.

One of the standout features of the Worth Data 7000 is its robust barcode scanning capabilities. Equipped with a high-quality scanner, it can read a wide range of barcode formats, including 1D and 2D barcodes. This versatility ensures that users can seamlessly integrate the device into existing systems and easily manage different types of inventory, thereby reducing errors and improving data collection accuracy.

The Worth Data 7000 leverages advanced wireless technology, including Bluetooth and Wi-Fi connectivity, allowing for real-time data transfer to cloud-based systems or local servers. This capability is crucial for businesses that require instantaneous updates and access to critical information across multiple locations. The device is also compatible with various mobile applications, enhancing its functionality and enabling users to perform transactions and updates remotely.

In terms of hardware, the Worth Data 7000 features a durable design that meets the demands of industrial and retail environments. Its rugged casing is designed to withstand drops, impacts, and exposure to dust and moisture, ensuring longevity and reliability in challenging conditions. The device is also equipped with an intuitive touchscreen interface, making it user-friendly and accessible, even for those with minimal technical skills.

Another important characteristic of the Worth Data 7000 is its long-lasting battery life. Designed for extended use, the device can operate for hours on a single charge, allowing employees to focus on their tasks without frequent interruptions for recharging. This is particularly beneficial in fast-paced environments where time is of the essence.

Furthermore, the Worth Data 7000 supports a variety of software applications that can be tailored to meet specific business needs. From inventory management systems to customized point-of-sale solutions, the device offers flexibility and scalability for businesses of all sizes.

In conclusion, the Worth Data 7000 stands out as a powerful tool for data collection and management, thanks to its superior barcode scanning capabilities, robust connectivity options, durable design, extended battery life, and flexibility in software applications. Whether for retail, warehouse management, or asset tracking, it is a reliable choice for businesses looking to enhance their operational efficiency and improve data accuracy.