Mode. Once the RF Terminal transmits data to the Base Station, the Base Station acknowledges receipt of the information by echoing back the data to the Terminal that sent it, along with a beep. If the data transmission did not make it through to the Base station after 10 tries, the RF Terminal will give two long beeps and display the following message:

TRANSMISSION FAILED

TO RETRY, MOVE CLOSER

AND PRESS ENTER.

F1 TO EXIT.

One-Way mode also works well as a test program since it doesn’t require a program running on the host computer or even that the Base Station be connected to the host. To get into One-WayMode:

Hit any key at the opening screen, then select option 3 from the MODE MENU.

If the Base Station already has other RF Terminals signed on in Two-Way mode, you will not be allowed into the system. A Base Station must be dedicated to one mode at a time.

If the Base Station is dedicated to One-Way mode, you will see the following prompt on the RF Terminal display:

Data Received Was

Enter Data?

Since you have just started your One-Way session, there is no data to display on line #2. Line #3 is now asking you to scan or key data into the RF Terminal. If you are entering data from the RF Terminal keypad, you must press the ENTER key to transmit your data. If the Base Station receives the data, the RF Terminal displays the following prompt:

Data Received Was aaaaaaaaaaaaaaaaaa Enter Data?

Where aaaaaaaaaaaaaaaaaa is the data received by the Base Station (and transmitted to the Host Computer if connected). You can exit One-Way Mode simply by pressing the F1 key on the RF Terminal keypad.

In One-Way Mode, the RF Terminal transmits its Terminal ID to the Base Station but it does not pass it on to the Host Computer. If your application on the Host Computer needs to know which RF Terminal data came from, use the Preamble setup parameter to enter unique identifying information. Data is also transmitted without a Terminator Character (like a CR or TAB that is transmitted after the data); so if you need one, use the Postamble setup parameter to add the appropriate character(s) after your data. For more information on Preambles and Postambles see Chapter 2; RF System Setup for details.

How Site Survey works

The RF Terminal uses Site Survey mode to: 1) test the radios at short range, (50 ft.) as an acid test for correct operation, and 2) to evaluate a specific site for effective coverage. Because each operating environment is different, it is almost impossible to predict the range without Site Survey.

Before you permanently install any hardware, you should perform a Site Survey to fully evaluate your planned area of operation. During the test the RF Terminal is transmitting messages and waiting for acknowledgment from the Base Station. (Since this US Terminal hops over 26 different frequencies, the Site Survey goes across all frequencies to make comparisons valid; this takes about 10 seconds.). The Site

Image 31
Contents Page Page Table of Contents Differences IntroductionPage Components InstallationInstallation Sequence Connecting the Base Station to a serial portConfiguring the Base station… Connecting the Base station…Base station channel… Battery too Low to Operate Hit Any Key to Power Down Using the RF Terminal keypad…Battery Life Indicator Charge Battery Hit Any KeyBattery Charge Complete To change the internal batteryRecharging the battery Charging Battery Please Wait………Terminal Menu Functions Opening screen can be bypassed upon power up. See ChapterFirmware Uxxx HWyy-Rzz Windows Demo Programs and RF DLL Programmers Library Installing the RF Terminal Utilities SoftwareUsing the Windows 7000 RF Terminal Loader Utility Installing the Windows Terminal Loader UtilityTerminal Eprom Loader Help Uninstall Using the Setup Menu on the RF Terminal RF System SetupSign On Setup One Way Mode RF Site Survey RF Terminal ID RF ConfigurationControl Keys Only RF Terminal ChannelSecurity Code Skip Opening ScreensAutomatic Check Back Bar Code OptionsCode 3 of 9 Code UPC-A / EAN-13 Options 5 Code UPC-E / EAN-8 OptionsCode CodabarCode 93 / Code MSI and PlesseyDataBar / RSS-14 Options RS-232 I/O Settings Year Output Set TimeSet Date Date FormatLaser Options Speaker SettingsLCD Options Preamble Other SettingsNnmm Postamble Settings menuDownload File Reset to Factory DefaultSystem Tools CharactersUsing the RF 7000 Configuration Utility Base and Relay SetupDataaaaaaaaCR Testing the RF link between base station and hostOperational Theory @@*EdataaaaaaaaEOTHere is how it works How the Two-Way RF System worksBasic RF System communications… Little more in depth…Can I change a prompt after it has been sent? How the One-Way RF System worksData Received Was Enter Data? How Site Survey worksEvaluating your area of planned operation Performance IssuesPerforming a Site Survey Site Testing in Progress Please Wait………… Press Enter When Ready or F1 to ExitHow Relay Stations work… Relay StationsRelay n Cannot be Relay Installation Is radio traffic contention likely?Determining coverage areas for Base Stations and Relays Before you begin programming… Hardware Failures Command without an IDOperator Errors Failure PlanningHost to Terminal Programming Programming for the RF TerminalLOW Level Ascii sequences directly Planning@Cfnfnfn...\cb Color Display Programming= White @n,m,o,data Where n m@1,1,1,ITEM@2,1,1,QTY Page @2,1,1,ENTER Item no Serial Reply Base Station to Host FormatsBase Shut Down Due to Host Logic Error Base Station Error FeedbackAddressing a Terminal not SIGNed on @1,1,1,Scan Serial Number Sequence Error MessageIllegal Command ?CRBase Station Initialized Message Control Keys for Possible ProgrammingPage Concepts ActiveX Object Programming PromptCOM/ActiveXValid values Properties ActiveX ObjectValid valuesNone, Even, Odd Line Terminal True, FalseMethods ActiveX Object Color Codes forParameters line, position, prompt, shifted Parameters line, position, promptParameters line, position, prompt, FG, BG Parameters line, position, prompt,FG,BGParameters font, linecount Events ActiveX Object Parameters FGcolor, BGcolorData passedterminal, data Data Passed TerminalServer Communications Programming Considerations Network SetupPromptNET TCP/IP Active X Controls Client UtilityTest For Good Communication Concepts TCP/IP COMRead Only ProblemsProperties TCP/IP COM Valid values blank or a valid file nameParameters basename, channel, terminal, count Parameters basename, channel, terminal, dataParameters basename, channel, terminal Parameters basename, channel, terminal, lineData passedbasename, channel Parameters basename, channel, terminal, msgnumParameters basename, channel Events TCP/IP COMData passedbasename, channel, terminal, data OnTermEndKey Cameo and QL 3 Common Information Portable PrintersZebra Cameo Printer Part Number Description Price/Roll Zebra QL 3 PrinterVoice Message Operations Why Use Voice Messages and Prompts?Tips for Using Voice Prompts Assigning Error MessagesDefault Voice Messages General Considerations TroubleshootingProblems with a new installation Changing the BatteryMessage Meaning Action Required Terminal Error MessagesMessage Meaning Action RequiredIm not getting the distance I need Troubleshooting specific problemsCan’t communicate at all My response time is poorReader wont beep when I try to read bar codes RF Terminal ProblemsProblems reading Bar Codes Get 6 beeps when the RF Terminal powers upHave very poor read rates when scanning bar codes If you have a problem…RMA #XXXXXX RS-422 Termination Jumpers Channel and Jumper ChangesOpening a Base Changing a Base to a RelayChannel Changes Connecting a Relay StationSetting the Relay ID Adding RelaysCorrect Routing for Wiring Routing the WiringRelay Station RS422 Pin-outs Incorrect Routing for WiringRelay Test Plan and Failures Relay Failure RS-422 Termination Testing the RelayChanging a Relay back to a Base Changing the Channel on a RelayF36 DB9 Straight Cable Serial Pin-outsBase Station to Host Pin-outs F34 DB25 Null Modem CableNormal Firmware Download for a Terminal Firmware UpgradesTerminal Firmware Upgrades Relay Station RS422 Pin-outsC39 Code 39 SpecificationsBase Station Firmware upgrades Failsafe Firmware Download for a TerminalValue 22 is the Check Character Code 39 Advanced Features and FunctionsMod 43 Check Character Mod 43 Check character calculation for CodeFull Ascii Extension to Code Accumulate ModeClear Enter Code 93 SpecificationsCodabar start/stop transmission Codabar SpecificationsCode 128 Specifications A12345bUCC-128 Shipping Container Code Interleaved 2 of 5 Code SpecificationsUPC / EAN Specifications Supplemental codes Isbn SpecificationsUPC/EAN checksum character MSI/Plessey Specifications Laser Scanners How to scan a bar codeAiming the Laser Dot Laser OptionsBEL Ascii Code Equivalent Table

7000 specifications

The Worth Data 7000 is an advanced data collection and management device designed for various applications, including inventory control, asset tracking, and point-of-sale transactions. This versatile handheld device excels in environments requiring efficiency and reliability, making it a popular choice for businesses looking to optimize their operational workflows.

One of the standout features of the Worth Data 7000 is its robust barcode scanning capabilities. Equipped with a high-quality scanner, it can read a wide range of barcode formats, including 1D and 2D barcodes. This versatility ensures that users can seamlessly integrate the device into existing systems and easily manage different types of inventory, thereby reducing errors and improving data collection accuracy.

The Worth Data 7000 leverages advanced wireless technology, including Bluetooth and Wi-Fi connectivity, allowing for real-time data transfer to cloud-based systems or local servers. This capability is crucial for businesses that require instantaneous updates and access to critical information across multiple locations. The device is also compatible with various mobile applications, enhancing its functionality and enabling users to perform transactions and updates remotely.

In terms of hardware, the Worth Data 7000 features a durable design that meets the demands of industrial and retail environments. Its rugged casing is designed to withstand drops, impacts, and exposure to dust and moisture, ensuring longevity and reliability in challenging conditions. The device is also equipped with an intuitive touchscreen interface, making it user-friendly and accessible, even for those with minimal technical skills.

Another important characteristic of the Worth Data 7000 is its long-lasting battery life. Designed for extended use, the device can operate for hours on a single charge, allowing employees to focus on their tasks without frequent interruptions for recharging. This is particularly beneficial in fast-paced environments where time is of the essence.

Furthermore, the Worth Data 7000 supports a variety of software applications that can be tailored to meet specific business needs. From inventory management systems to customized point-of-sale solutions, the device offers flexibility and scalability for businesses of all sizes.

In conclusion, the Worth Data 7000 stands out as a powerful tool for data collection and management, thanks to its superior barcode scanning capabilities, robust connectivity options, durable design, extended battery life, and flexibility in software applications. Whether for retail, warehouse management, or asset tracking, it is a reliable choice for businesses looking to enhance their operational efficiency and improve data accuracy.