Worth Data 7000 How the One-Way RF System works, Can I change a prompt after it has been sent?

Page 30

Lets suppose that a RF Terminal and a Base Station have been processing data by sending prompts and data back and forth as described in example 1. The Base Station sends a data prompt to the RF Terminal, the RF Terminal transmits the operator-entered data back to the Base Station. If the host program has another prompt for the terminal, the Base sends it out, repeating the process above.

Suppose the host program does not have a prompt ready to send back to the Terminal; the Terminal transmits its data to the Base Station but does not receive a new data prompt. The Terminal then retransmits its data (it thinks maybe the host didn’t receive it) and waits for a response.

Once the terminal has received a prompt back from the host, the time it took the host to respond is sent to the Terminal. For all subsequent transmissions, the terminal goes to sleep until the time it took the last time for the host to respond has expired; then the terminal wakes up and listens. If it has nothing, it retransmits its data and waits for a response.

The original data transmission could have collided with another message, or the Base could have received the Terminal's data but had not yet received the host's prompt response. If the previous transmission got through, the Base Station knows that the data is a retransmission rather than a new data transmission so it sends a message to the Terminal telling it:

“I have nothing for you from the host, go to sleep”.

While in “sleep” mode, the Terminal “wakes” up at a random interval and asks “do you have anything for me yet”, waiting for either a “go to sleep” message or a new data prompt. After each delays, the Terminal displays:

WAITING FOR HOST PROMPT

If a Terminal receives no response at all from a Base Station (no data prompt or “go to sleep” message), it retransmits its data and waits for a response. If the Terminal gets no response after 10 re-transmissions, it assumes it is out of range from the Base Station with which it was communicating, and attempts of establish contact with any Base Station. If the Terminal can't contact any Base Station, it displays:

TRANSMISSION FAILED

HIT ANY KEY_

Pressing a key on the Terminal starts the re-transmission process over again. The RF Terminal will try to retransmit its data, displaying the TRANSMISSION FAILED message after every 10 unsuccessful tries.

Can I change a prompt after it has been sent?

Normally once the Terminal has received a prompt from the host, it goes to sleep and waits (as long as it takes) for the operator to scan or key something in response. The host cannot send another prompt without creating a "Sequence Error." You might want to change the prompt or locate a lost terminal with beeping.

There is a special setting in the RF Terminal Setup in which you specify the time (between 5 seconds and 7 minutes) you want the Terminal to quit waiting for input from the operator, blank the screen, send back a special control character to the host program, display "Waiting on Host Prompt" and wait for a prompt from the host application program; the host application program can choose to send back different instructions or simply repeat the previous prompt's instructions, (See Automatic Check Back in the Programming Section).

How the One-Way RF System works

The RF System can be used to perform “dumb” data entry to the computer – you could even use Portkey to transmit the data through a serial connected Base as though it has been entered from the keyboard. This is useful if you want to enter data directly into an application. This type of data transmission is called One-Way

Image 30
Contents Page Page Table of Contents Introduction DifferencesPage Connecting the Base Station to a serial port InstallationInstallation Sequence ComponentsConnecting the Base station… Configuring the Base station…Base station channel… Charge Battery Hit Any Key Using the RF Terminal keypad…Battery Life Indicator Battery too Low to Operate Hit Any Key to Power DownCharging Battery Please Wait……… To change the internal batteryRecharging the battery Battery Charge CompleteOpening screen can be bypassed upon power up. See Chapter Terminal Menu FunctionsFirmware Uxxx HWyy-Rzz Installing the Windows Terminal Loader Utility Installing the RF Terminal Utilities SoftwareUsing the Windows 7000 RF Terminal Loader Utility Windows Demo Programs and RF DLL Programmers LibraryTerminal Eprom Loader Help Uninstall RF System Setup Using the Setup Menu on the RF TerminalSign On Setup One Way Mode RF Site Survey RF Configuration RF Terminal IDSkip Opening Screens RF Terminal ChannelSecurity Code Control Keys OnlyBar Code Options Automatic Check BackCode 3 of 9 Code UPC-A / EAN-13 Options Codabar UPC-E / EAN-8 OptionsCode 5 CodeMSI and Plessey Code 93 / CodeDataBar / RSS-14 Options RS-232 I/O Settings Date Format Set TimeSet Date Year OutputSpeaker Settings Laser OptionsLCD Options Other Settings PreambleNnmm Settings menu PostambleCharacters Reset to Factory DefaultSystem Tools Download FileBase and Relay Setup Using the RF 7000 Configuration Utility@@*EdataaaaaaaaEOT Testing the RF link between base station and hostOperational Theory DataaaaaaaaCRLittle more in depth… How the Two-Way RF System worksBasic RF System communications… Here is how it worksHow the One-Way RF System works Can I change a prompt after it has been sent?How Site Survey works Data Received Was Enter Data?Performance Issues Evaluating your area of planned operationPerforming a Site Survey Press Enter When Ready or F1 to Exit Site Testing in Progress Please Wait…………Relay Stations How Relay Stations work…Relay n Cannot be Is radio traffic contention likely? Relay InstallationDetermining coverage areas for Base Stations and Relays Before you begin programming… Failure Planning Command without an IDOperator Errors Hardware FailuresPlanning Programming for the RF TerminalLOW Level Ascii sequences directly Host to Terminal ProgrammingColor Display Programming @Cfnfnfn...\cb= White Where n m @n,m,o,data@1,1,1,ITEM@2,1,1,QTY Page @2,1,1,ENTER Item no Base Station to Host Formats Serial ReplyBase Station Error Feedback Base Shut Down Due to Host Logic ErrorAddressing a Terminal not SIGNed on ?CR Sequence Error MessageIllegal Command @1,1,1,Scan Serial NumberControl Keys for Possible Programming Base Station Initialized MessagePage PromptCOM/ActiveX Concepts ActiveX Object ProgrammingProperties ActiveX Object Valid valuesValid valuesNone, Even, Odd Color Codes for True, FalseMethods ActiveX Object Line TerminalParameters line, position, prompt,FG,BG Parameters line, position, promptParameters line, position, prompt, FG, BG Parameters line, position, prompt, shiftedParameters font, linecount Parameters FGcolor, BGcolor Events ActiveX ObjectData passedterminal, data Terminal Data PassedClient Utility Programming Considerations Network SetupPromptNET TCP/IP Active X Controls Server CommunicationsConcepts TCP/IP COM Test For Good CommunicationValid values blank or a valid file name ProblemsProperties TCP/IP COM Read OnlyParameters basename, channel, terminal, line Parameters basename, channel, terminal, dataParameters basename, channel, terminal Parameters basename, channel, terminal, countEvents TCP/IP COM Parameters basename, channel, terminal, msgnumParameters basename, channel Data passedbasename, channelData passedbasename, channel, terminal, data OnTermEndKey Portable Printers Cameo and QL 3 Common InformationZebra Cameo Printer Zebra QL 3 Printer Part Number Description Price/RollAssigning Error Messages Why Use Voice Messages and Prompts?Tips for Using Voice Prompts Voice Message OperationsDefault Voice Messages Changing the Battery TroubleshootingProblems with a new installation General ConsiderationsMeaning Action Required Terminal Error MessagesMessage Message Meaning Action RequiredMy response time is poor Troubleshooting specific problemsCan’t communicate at all Im not getting the distance I needGet 6 beeps when the RF Terminal powers up RF Terminal ProblemsProblems reading Bar Codes Reader wont beep when I try to read bar codesIf you have a problem… Have very poor read rates when scanning bar codesRMA #XXXXXX Changing a Base to a Relay Channel and Jumper ChangesOpening a Base RS-422 Termination JumpersAdding Relays Connecting a Relay StationSetting the Relay ID Channel ChangesRouting the Wiring Correct Routing for WiringIncorrect Routing for Wiring Relay Station RS422 Pin-outsRelay Test Plan and Failures Relay Failure Changing the Channel on a Relay Testing the RelayChanging a Relay back to a Base RS-422 TerminationF34 DB25 Null Modem Cable Serial Pin-outsBase Station to Host Pin-outs F36 DB9 Straight CableRelay Station RS422 Pin-outs Firmware UpgradesTerminal Firmware Upgrades Normal Firmware Download for a TerminalFailsafe Firmware Download for a Terminal Code 39 SpecificationsBase Station Firmware upgrades C39Mod 43 Check character calculation for Code Code 39 Advanced Features and FunctionsMod 43 Check Character Value 22 is the Check CharacterAccumulate Mode Full Ascii Extension to CodeCode 93 Specifications Clear EnterA12345b Codabar SpecificationsCode 128 Specifications Codabar start/stop transmissionInterleaved 2 of 5 Code Specifications UCC-128 Shipping Container CodeUPC / EAN Specifications Isbn Specifications Supplemental codesUPC/EAN checksum character MSI/Plessey Specifications How to scan a bar code Laser ScannersLaser Options Aiming the Laser DotAscii Code Equivalent Table BEL

7000 specifications

The Worth Data 7000 is an advanced data collection and management device designed for various applications, including inventory control, asset tracking, and point-of-sale transactions. This versatile handheld device excels in environments requiring efficiency and reliability, making it a popular choice for businesses looking to optimize their operational workflows.

One of the standout features of the Worth Data 7000 is its robust barcode scanning capabilities. Equipped with a high-quality scanner, it can read a wide range of barcode formats, including 1D and 2D barcodes. This versatility ensures that users can seamlessly integrate the device into existing systems and easily manage different types of inventory, thereby reducing errors and improving data collection accuracy.

The Worth Data 7000 leverages advanced wireless technology, including Bluetooth and Wi-Fi connectivity, allowing for real-time data transfer to cloud-based systems or local servers. This capability is crucial for businesses that require instantaneous updates and access to critical information across multiple locations. The device is also compatible with various mobile applications, enhancing its functionality and enabling users to perform transactions and updates remotely.

In terms of hardware, the Worth Data 7000 features a durable design that meets the demands of industrial and retail environments. Its rugged casing is designed to withstand drops, impacts, and exposure to dust and moisture, ensuring longevity and reliability in challenging conditions. The device is also equipped with an intuitive touchscreen interface, making it user-friendly and accessible, even for those with minimal technical skills.

Another important characteristic of the Worth Data 7000 is its long-lasting battery life. Designed for extended use, the device can operate for hours on a single charge, allowing employees to focus on their tasks without frequent interruptions for recharging. This is particularly beneficial in fast-paced environments where time is of the essence.

Furthermore, the Worth Data 7000 supports a variety of software applications that can be tailored to meet specific business needs. From inventory management systems to customized point-of-sale solutions, the device offers flexibility and scalability for businesses of all sizes.

In conclusion, the Worth Data 7000 stands out as a powerful tool for data collection and management, thanks to its superior barcode scanning capabilities, robust connectivity options, durable design, extended battery life, and flexibility in software applications. Whether for retail, warehouse management, or asset tracking, it is a reliable choice for businesses looking to enhance their operational efficiency and improve data accuracy.