Worth Data 7000 manual Postamble, Settings menu

Page 25

lengths, no decode will result. Entering data by keypad is not affected.

Postamble

Postambles are user-defined data that is attached to the end of data (bar code or keyed) that is transmitted to the host by the RF Terminal. For example, if you set a Postamble of @@ and scanned bar code data of 12345, 12345@@ would be transmitted to the host.

By default, the RF Terminal has no Postambles configured. Postambles can contain up to 15 characters.

To set a Postamble:

1 Select option “8” from the RF Terminal Setup menu then “2” for

Postamble from the Other

Settings menu.

 

2 Enter the desired characters (up to 15). Pressing the shift key will turn the cursor red to indicate

that the shift is active. Pressing shift again will turn the cursor white and return to unshifted mode..

3 Press “ENTER”.when you are finished entering data.

To clear the Postamble and return to the default (no Postamble defined), press “CLEAR”.

You can use the Postamble to trim characters from the data you are entering into the RF Terminal. You can trim from 1-15 characters from the data by creating a Postamble of:

~x

where ~ is ASCII 126 and x is a single hex digit 1-F (corresponding to 1-15). Data that is shorter than the trim amount is transmitted without trimming. Postambles trim characters from the end of the data. Here are some examples:

Data

Postamble

Data Transmitted

123

XYZ

123XYZ

12345678

~3XYZ

12345XYZ

12345678

~9

12345678

12345678901

~A

1

123456

~5

1

 

Postamble trims trailing characters

Using the Bar Code ID feature and the Postamble, you can trim data selectively, trimming characters only on the bar code type specified. To use selective trimming, enter:

~bx

where b is the Bar Code ID character (see the Code 128 setup parameter) and x is the number of characters to trim from the end of the data. For example, ~b2~c1 says “trim 2 characters from Code 39 data and 1 character from UPC-A data”. Remember that the Postamble trims trailing data.

Lastly, the Postamble can be used to check a maximum character length for data entered. To check for length in the Postamble, enter:

nnmm

where is ASCII 124, nn is the two-digit minimum and mm is the two-digit maximum. 0210 would check for a minimum of 2 characters and a maximum of 10 If you try to scan a bar code outside the minimum or maximum lengths, no decode will result. Entering data by keypad is not affected.

Image 25
Contents Page Page Table of Contents Differences IntroductionPage Installation Sequence InstallationConnecting the Base Station to a serial port ComponentsConfiguring the Base station… Connecting the Base station…Base station channel… Battery Life Indicator Using the RF Terminal keypad…Charge Battery Hit Any Key Battery too Low to Operate Hit Any Key to Power DownRecharging the battery To change the internal batteryCharging Battery Please Wait……… Battery Charge CompleteTerminal Menu Functions Opening screen can be bypassed upon power up. See ChapterFirmware Uxxx HWyy-Rzz Using the Windows 7000 RF Terminal Loader Utility Installing the RF Terminal Utilities SoftwareInstalling the Windows Terminal Loader Utility Windows Demo Programs and RF DLL Programmers LibraryTerminal Eprom Loader Help Uninstall Using the Setup Menu on the RF Terminal RF System SetupSign On Setup One Way Mode RF Site Survey RF Terminal ID RF ConfigurationSecurity Code RF Terminal ChannelSkip Opening Screens Control Keys OnlyAutomatic Check Back Bar Code OptionsCode 3 of 9 Code UPC-A / EAN-13 Options Code UPC-E / EAN-8 OptionsCodabar 5 CodeCode 93 / Code MSI and PlesseyDataBar / RSS-14 Options RS-232 I/O Settings Set Date Set TimeDate Format Year OutputLaser Options Speaker SettingsLCD Options Preamble Other SettingsNnmm Postamble Settings menuSystem Tools Reset to Factory DefaultCharacters Download FileUsing the RF 7000 Configuration Utility Base and Relay SetupOperational Theory Testing the RF link between base station and host@@*EdataaaaaaaaEOT DataaaaaaaaCRBasic RF System communications… How the Two-Way RF System worksLittle more in depth… Here is how it worksCan I change a prompt after it has been sent? How the One-Way RF System worksData Received Was Enter Data? How Site Survey worksEvaluating your area of planned operation Performance IssuesPerforming a Site Survey Site Testing in Progress Please Wait………… Press Enter When Ready or F1 to ExitHow Relay Stations work… Relay StationsRelay n Cannot be Relay Installation Is radio traffic contention likely?Determining coverage areas for Base Stations and Relays Before you begin programming… Operator Errors Command without an IDFailure Planning Hardware FailuresLOW Level Ascii sequences directly Programming for the RF TerminalPlanning Host to Terminal Programming@Cfnfnfn...\cb Color Display Programming= White @n,m,o,data Where n m@1,1,1,ITEM@2,1,1,QTY Page @2,1,1,ENTER Item no Serial Reply Base Station to Host FormatsBase Shut Down Due to Host Logic Error Base Station Error FeedbackAddressing a Terminal not SIGNed on Illegal Command Sequence Error Message?CR @1,1,1,Scan Serial NumberBase Station Initialized Message Control Keys for Possible ProgrammingPage Concepts ActiveX Object Programming PromptCOM/ActiveXValid values Properties ActiveX ObjectValid valuesNone, Even, Odd Methods ActiveX Object True, FalseColor Codes for Line TerminalParameters line, position, prompt, FG, BG Parameters line, position, promptParameters line, position, prompt,FG,BG Parameters line, position, prompt, shiftedParameters font, linecount Events ActiveX Object Parameters FGcolor, BGcolorData passedterminal, data Data Passed TerminalPromptNET TCP/IP Active X Controls Programming Considerations Network SetupClient Utility Server CommunicationsTest For Good Communication Concepts TCP/IP COMProperties TCP/IP COM ProblemsValid values blank or a valid file name Read OnlyParameters basename, channel, terminal Parameters basename, channel, terminal, dataParameters basename, channel, terminal, line Parameters basename, channel, terminal, countParameters basename, channel Parameters basename, channel, terminal, msgnumEvents TCP/IP COM Data passedbasename, channelData passedbasename, channel, terminal, data OnTermEndKey Cameo and QL 3 Common Information Portable PrintersZebra Cameo Printer Part Number Description Price/Roll Zebra QL 3 PrinterTips for Using Voice Prompts Why Use Voice Messages and Prompts?Assigning Error Messages Voice Message OperationsDefault Voice Messages Problems with a new installation TroubleshootingChanging the Battery General ConsiderationsMessage Terminal Error MessagesMeaning Action Required Message Meaning Action RequiredCan’t communicate at all Troubleshooting specific problemsMy response time is poor Im not getting the distance I needProblems reading Bar Codes RF Terminal ProblemsGet 6 beeps when the RF Terminal powers up Reader wont beep when I try to read bar codesHave very poor read rates when scanning bar codes If you have a problem…RMA #XXXXXX Opening a Base Channel and Jumper ChangesChanging a Base to a Relay RS-422 Termination JumpersSetting the Relay ID Connecting a Relay StationAdding Relays Channel ChangesCorrect Routing for Wiring Routing the WiringRelay Station RS422 Pin-outs Incorrect Routing for WiringRelay Test Plan and Failures Relay Failure Changing a Relay back to a Base Testing the RelayChanging the Channel on a Relay RS-422 TerminationBase Station to Host Pin-outs Serial Pin-outsF34 DB25 Null Modem Cable F36 DB9 Straight CableTerminal Firmware Upgrades Firmware UpgradesRelay Station RS422 Pin-outs Normal Firmware Download for a TerminalBase Station Firmware upgrades Code 39 SpecificationsFailsafe Firmware Download for a Terminal C39Mod 43 Check Character Code 39 Advanced Features and FunctionsMod 43 Check character calculation for Code Value 22 is the Check CharacterFull Ascii Extension to Code Accumulate ModeClear Enter Code 93 SpecificationsCode 128 Specifications Codabar SpecificationsA12345b Codabar start/stop transmissionUCC-128 Shipping Container Code Interleaved 2 of 5 Code SpecificationsUPC / EAN Specifications Supplemental codes Isbn SpecificationsUPC/EAN checksum character MSI/Plessey Specifications Laser Scanners How to scan a bar codeAiming the Laser Dot Laser OptionsBEL Ascii Code Equivalent Table

7000 specifications

The Worth Data 7000 is an advanced data collection and management device designed for various applications, including inventory control, asset tracking, and point-of-sale transactions. This versatile handheld device excels in environments requiring efficiency and reliability, making it a popular choice for businesses looking to optimize their operational workflows.

One of the standout features of the Worth Data 7000 is its robust barcode scanning capabilities. Equipped with a high-quality scanner, it can read a wide range of barcode formats, including 1D and 2D barcodes. This versatility ensures that users can seamlessly integrate the device into existing systems and easily manage different types of inventory, thereby reducing errors and improving data collection accuracy.

The Worth Data 7000 leverages advanced wireless technology, including Bluetooth and Wi-Fi connectivity, allowing for real-time data transfer to cloud-based systems or local servers. This capability is crucial for businesses that require instantaneous updates and access to critical information across multiple locations. The device is also compatible with various mobile applications, enhancing its functionality and enabling users to perform transactions and updates remotely.

In terms of hardware, the Worth Data 7000 features a durable design that meets the demands of industrial and retail environments. Its rugged casing is designed to withstand drops, impacts, and exposure to dust and moisture, ensuring longevity and reliability in challenging conditions. The device is also equipped with an intuitive touchscreen interface, making it user-friendly and accessible, even for those with minimal technical skills.

Another important characteristic of the Worth Data 7000 is its long-lasting battery life. Designed for extended use, the device can operate for hours on a single charge, allowing employees to focus on their tasks without frequent interruptions for recharging. This is particularly beneficial in fast-paced environments where time is of the essence.

Furthermore, the Worth Data 7000 supports a variety of software applications that can be tailored to meet specific business needs. From inventory management systems to customized point-of-sale solutions, the device offers flexibility and scalability for businesses of all sizes.

In conclusion, the Worth Data 7000 stands out as a powerful tool for data collection and management, thanks to its superior barcode scanning capabilities, robust connectivity options, durable design, extended battery life, and flexibility in software applications. Whether for retail, warehouse management, or asset tracking, it is a reliable choice for businesses looking to enhance their operational efficiency and improve data accuracy.