5.10Interior light

Changing the light bulbs

1. Remove cover.

4.Clip the cover back in place.

1.

2.

90°

 

 

 

2. Detach defective light

3. Fit new light bulb

bulb.

 

 

Note:

For 12V DC :

1 light bulb 12V, 2W

Please contact Dometic Service Centres for

replacement light bulbs.

5.11Changing the decor panel

1.Upper door

A

B

-remove the two screws holding the control panel

-unsrcew upper hinge pin (A) and remove the door

-unscrew upper part of the door frame and the panel

-insert new panel and fasten upper part of the door frame

Please note: Carry out following steps BEFORE moun- ting the upper door.

2. Lower door

- unscrew both screws of the middle hinge pin (B)

-Pull out door and hinge in an upwards direction

-unsrcrew lower part of the door frame and remove the decor panel

-insert new panel and fasten lower part of the door frame

-insert lower door and fasten the middle hinge

-insert upper door and fasten the upper hinge pin (A)

-replace the control panel

Dimensions of the panels in mm:

Model

 

Height

Width

Thickness

RM 7601/ RM 7605

(flat door)

857,0+/-1

491,5+0/-1

3,2 max

 

 

252,5+/-1

491,5+0/-1

3,2 max

RM 7651/ RM 7655

(curved door)

868,0+/-1

500,0+0/-1

2,5 max

 

 

263,0+/-1

500,0+0/-1

2,5 max

13

Image 13
Contents Manual Safety instructions Table of Contents Coolant IntroductionDamage in transit CleaningControls Using the refrigeratorManual energy selection MES RM 76x1 L Automatic and manual energy selection AES RM 76x5 LElectrical operation Mains power12V operation DC AUTO-operation Gas operationExplanations Operation Gas faults RM 76x1 and RMGas operation Storing food Temperature setting cooling compartmentFrame heating Additional functions RM 76x5 onlyDefrosting Making ice cubesPositioning the storage rack DismantlingDoor locking Switching offWinter operation Changing the decor panel Interior lightChanging the doorhang Troubleshooting Product liability MaintenanceEnvironmental hints DisposalDeclaration of conformity Technical dataSide installation InstallationRear installation Comment Draught-free installationVentilation and extraction Installation of lower and upper ventila- tion grilles L500500 Installing the ventilation systemSecuring the refrigerator Installation recessGas installation Connections for gas / electrical installationGas-pressure Power line connection Electrical installationBattery connection Retrofitting From the manual energy mode to the automatic energy modeSolar control input S+ Wiring diagram for RM 76x1 L Wiring diagramWiring diagram for RM 76x5 L Page Dometic GmbH Der Steinwiese Siegen