Inflamable material should not be in immediate proximity to the burner.
The gas connection to the appliance is effected by means of a suitable coupling tube fitting L8, DIN
The gas connection may only be carried out by a qualified personnel.
Following proper installation, a testing for leakage and a flame test must be car- ried out by *qualified personnel in compliance with EN 1949 .
A certificate of testing must be issued.
* qualified personnel
Qualified personnel are accredited experts who are able, by virtue of their training and knowledge, to vouch for the correct implementation of the leakage test.
ATTENTION
15 Nm |
| 20 Nm |
max |
| max |
|
|
|
SW 14 SW 17
C
The refrigerator must be equipped with a gas cock
(C) in the supply line to allow the supply to be disconnected. Such a
Gas-pressure
Category | I3P(30) | I 3P(37) | I3P(50) |
| I3+ | I3B/P(50) | I3B/P(30) |
mbar | 30 | 37 | 50 | 50 | 30 | ||
|
|
|
|
|
|
|
|
BE |
|
|
| X |
|
|
|
DK |
|
|
|
|
|
| X |
DE |
|
|
|
|
| X | X |
FI |
|
|
|
|
|
| X |
FR |
|
|
| X |
|
|
|
GR |
|
|
|
| X |
| X |
IE |
| X |
| X |
|
|
|
IS |
|
|
|
|
|
| X |
IT |
|
|
| X |
|
|
|
LU | X |
|
|
|
|
| X |
NL | X |
|
|
|
|
| X |
NO |
|
|
|
|
|
| X |
AT |
|
|
|
|
| X | X |
PT |
| X |
|
| X |
|
|
SE |
|
|
|
|
|
| X |
CH |
|
|
| X |
|
| X |
ES |
|
|
| X |
|
|
|
UK |
| X |
| X |
|
| X |
24