Dometic RM 7601 L, RM 7651 L, RM 7655 L, RM 7605 L Draught-free installation, Comment

Page 19

6.2Draught-free installation

The refrigerator must be sealed in accordance with EN 1949.

Illustrated below is a typical approved method of sealing.

Proposal :

 

 

 

 

 

 

Using the Installation Sealing Kit from Dometic

 

 

 

 

 

FIG. 1

 

B

 

 

 

 

 

 

 

(available from Dometic)

 

 

 

 

 

 

 

 

 

Insert lipped seals (A) into the installation recesses

 

 

 

 

 

 

 

 

 

 

 

 

at the bottom and at each side (FIG 1, 2, 3).

 

 

 

 

 

 

Insert deflector plate (B), fitted with a lipped seal (A)

 

 

 

 

 

 

 

 

 

 

 

 

of heavy-duty, non- flammable material, into the

 

 

 

 

 

 

installation recess (see Fig. 4).

 

 

 

 

 

 

Insert deflector plate (B) in such a way that the hot

 

 

 

 

 

 

air escapes through the air vent grille into the open

 

 

 

 

 

 

air. Affix the discharge plate to the caravan wall, not

 

 

 

A

 

 

to the refrigerator !

 

 

 

 

 

 

In addition, discharge plate (B) with its lipped seal

 

 

 

 

 

 

(A)must seal the refrigerator off from the living area (see FIG. 1,4).

Ensure that the refrigerator is installed level in the recess.

B

A

A

FIG. 2

FIG. 3

FIG. 4

Finally, push the refrigerator into the recess from the front.

This installation option facilitates the removal and installation of the appliance for servicing.

Comment:

Other methods of sealing may be approved. However the chosen method must pre- vent draughts entering the living space of the motorhome. Failure to seal correctly will allow warm air to collect around the refrigerator and its performance will be affected. If the cavity between the vehicle’s wall and the refrigerator is sealed so that fumes cannot penetrate the living area it is possible to vent the flue gas directly through the upper grille

Do not use any kind of aluminium flue pipe (e.g. T-piece) to lead the flue gas out.

Deviations shall require the consent of the manufacturer.

19

Image 19
Contents Manual Safety instructions Table of Contents Coolant IntroductionDamage in transit CleaningAutomatic and manual energy selection AES RM 76x5 L Using the refrigeratorControls Manual energy selection MES RM 76x1 LElectrical operation Mains power12V operation DC AUTO-operation Gas operationExplanations Operation Gas faults RM 76x1 and RMGas operation Additional functions RM 76x5 only Temperature setting cooling compartmentStoring food Frame heatingDismantling Making ice cubesDefrosting Positioning the storage rackDoor locking Switching offWinter operation Changing the decor panel Interior lightChanging the doorhang Troubleshooting Disposal MaintenanceProduct liability Environmental hintsDeclaration of conformity Technical dataSide installation InstallationRear installation Comment Draught-free installationVentilation and extraction Installation of lower and upper ventila- tion grilles L500500 Installing the ventilation systemSecuring the refrigerator Installation recessGas installation Connections for gas / electrical installationGas-pressure Power line connection Electrical installationBattery connection Retrofitting From the manual energy mode to the automatic energy modeSolar control input S+ Wiring diagram for RM 76x1 L Wiring diagramWiring diagram for RM 76x5 L Page Dometic GmbH Der Steinwiese Siegen