Dometic RM 7601 L, RM 7651 L Connections for gas / electrical installation, Gas installation

Page 23

6.7Connections for gas / electrical installation

Terminal block 12VDC permanent connection

Terminal block

12VDC heating element

Gas valve

connection gas supply

Terminal block

12V DC conn. power module and D+ input

6.8Gas installation

￿The rules in point 6.1 must be adhered to.

￿When running on gas, these appliances are intended exclusively to use liquid gas (propane/butane) - under no circumstances should town gas or natural gas be used (EN 27418).

￿A fixed, pre-set pressure regulator complying with EN 12864 must be connected to the liquid gas cylinder.

￿The pressure regulator must concur with the operating pressure specified on the data plate of the appliance. The operating pressure corresponds to the standard pressure of the country of specification (EN 1949, EN 732).

￿Only one connection pressure is permissible for any one vehicle. A plate showing the permanent, clearly legible notice must be displayed in full view at the point where the gas cylinder is installed.

￿The gas connection to the appliance must be installed securely and at

zero potential using tube connectors and must be securely connected to the vehicle (a hose connection is not permissible) (EN 1949) .

23

Image 23
Contents Manual Safety instructions Table of Contents Coolant IntroductionDamage in transit CleaningAutomatic and manual energy selection AES RM 76x5 L Using the refrigeratorControls Manual energy selection MES RM 76x1 L12V operation DC Mains powerElectrical operation Explanations Gas operationAUTO-operation Gas operation Gas faults RM 76x1 and RMOperation Additional functions RM 76x5 only Temperature setting cooling compartmentStoring food Frame heatingDismantling Making ice cubesDefrosting Positioning the storage rackWinter operation Switching offDoor locking Changing the decor panel Interior lightChanging the doorhang Troubleshooting Disposal MaintenanceProduct liability Environmental hintsDeclaration of conformity Technical dataRear installation InstallationSide installation Comment Draught-free installationVentilation and extraction Installation of lower and upper ventila- tion grilles L500500 Installing the ventilation systemSecuring the refrigerator Installation recessGas installation Connections for gas / electrical installationGas-pressure Battery connection Electrical installationPower line connection Solar control input S+ From the manual energy mode to the automatic energy modeRetrofitting Wiring diagram for RM 76x1 L Wiring diagramWiring diagram for RM 76x5 L Page Dometic GmbH Der Steinwiese Siegen